Hanna Instruments (M) Sdn Bhd
11A, Jalan PJS 11/20,
Bandar Sunway,
46150 Petaling Jaya,
Selangor, Malaysia.
Penang Branch Office
Hanna Instruments (M) Sdn Bhd
N0. 303-2-27, Krystal Point,
Jalan Sultan Azlan Shah,
11900 Sungai Nibong,
Penang, Malaysia.
+604-638 4558
+604-645 4558
penang@hannamalaysia.com
Sabah Branch Office
Hanna Instruments (M) Sdn Bhd
No. 4-1, 1st Floor,
Plaza Kingfisher,
Jalan Plaza Kingfisher 5,
Inanam, 88450 Kota Kinabalu,
Sabah, East Malaysia.
088-382 941
088-382 942
sabah@hannamalaysia.com
HI84529-50 Low Range 20 Titrant for Titratable Acidity in Dairy Mini Titrator
Previous | 41 / 52 | Next |
RM 165.00
The HI84529 mini titrator measures acidity in two different ranges (high and low), as well as offering two different sample sizes to choose from when performing a low range measurement (20 and 50). There are three different titrant solutions available based on the range to be used and the weight of the sample, each having a different concentration.
The HI84529-50 is for titration in the low range (0.01 to 0.20 %l.a.) using a 20 mL or 20 g sample. The titrant is pre-standardized, eliminating the need for any volumetric glassware or a analytical balance and making titrations fast, accurate, and simple to perform.
- Pre-standardized titrant
- Clearly marked expiration date and lot number
- Air tight bottle with tamper-proof seal
-
Details
The HI84529-50 is a 120 mL bottle of alkaline titrant solution used for the Low Range 20 range that determines 0.01 to 0.20% lactic acid in dairy products.
The methodology for titratable acidity in dairy products is based on a neutralization reaction of the acids in a sample (e.g., lactic acid) with a base (e.g., sodium hydroxide) to produce water:
H++OH- → H2O
In an ideal solution, the endpoint of an acid titration corresponds stoichiometrically to the complete neutralization of the acids present. The endpoint for this reaction can be determined visually using a color indicator (e.g., phenolphthalein); however, this endpoint becomes very subjective in opaque and colored samples such as milk. The HI84529 removes this issue by titrating to a fixed pH endpoint that is potentiometrically determined by the FC260B half-cell pH electrode and HI5315 half-cell reference electrode.
Replacement reagents required to operate the HI84529 include:
Low Range 20 (LR 20) - %l.a.: 0.01 to 0.20
Low Range 50 (LR 50) - %l.a.: 0.01 to 0.20
High Range 20 (HR 20) - %l.a.: 0.1 to 2.0
Pump calibration standard
HI84529-55
HI84529-55
HI84529-55
Titrant solution
HI84529-50
HI84529-52
HI84529-51
-
Specifications
Package bottles Size 120 mL Quantity 1