Hanna Instruments (M) Sdn Bhd added 2 new photos in Photometers - Portable Photometers
15 hours ago —
HI97738 Chlorine Dioxide Portable Photometer with CAL Check
HI97749 Chromium (VI) Low-Range Portable Photometer with CAL Check
HI97779 Chlorine Dioxide (Rapid) Photometer with CAL Check

HI97779 Chlorine Dioxide (Rapid) Photometer with CAL Check

RM 1,672.00

HI97779 is an advanced portable photometer for the measurement of chlorine dioxide in water. This meter offers a superior optical system that utilizes a reference detector and narrow band interference filters for extremely fast and repeatable measurements.   No warm up time before taking a measurement Tutorial mode for step-by-step instructions CAL Check to verify meter performance Used primarily as a disinfectant in drinking water and in various industrial processes, chlorine dioxide is a highly effective, environmentally friendly microbiocide. Chlorine dioxide is safe, potent, and does not produce trihalomethanes, the disinfection byproduct characteristic of chlorine use. The HI97779 uses an adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 4500 ClO2D to measure chlorine dioxide concentrations of less than 2.00 mg/L (ppm). When the chlorophenol red reagent is added to samples containing chlorine dioxide, the purple hue from the reagent will lessen. The greater the concentration, the greater the discoloration. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complementary color, and the emitted radiation is dependent upon concentration. For chlorine dioxide determination, a narrow band interference filter at 525 nm allows only green-yellow light to be emitted and passed through the sample cuvette. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases. Using a pre-programmed curve a result is then displayed. The HI97779 has an innovative optical system that offers superior performance in accuracy, repeatability, and the short amount of time it takes to perform a measurement. This compact, waterproof meter is extremely user friendly with a tutorial mode that walks the user graphically, step by step, in performing a measurement. The use of a backlit dot matrix LCD allows the use of virtual keys which makes the operation of the meter very intuitive including selecting different units of measure, reviewing GLP data, recalling the last 50 measurements, and customizing the meter to user preferences. HI97779 is completely waterproof including the cuvette holder that is designed with ridges to protect the optical path from getting scratched by the cuvette and a gasketed battery compartment that holds three common AA batteries. The compact design fits comfortably in the hand for use in the field or on a table for benchtop use. The LCD is backlit for easy viewing under all conditions.   LED that generates very little heat 8 nm narrowband interference filter that is accurate to +/- 1 nm. Reference detector that modulates the voltage to LED for consistent light output.  A concave focusing lens that reduces errors from imperfections in the cuvette.   On-Screen Features CAL Check Advanced features including CAL-Check to verify performance and if necessary, recalibrate. Setup Options Setup options for meter personalization include date and time format, language, and enabling the tutorial mode. Tutorial Mode Tutorial mode for step-by-step instructions to guide a first-time user in how to perform a measurement correctly.   HI97779 FEATURES/BENEFITS: Stable Light Source: The internal reference system of the HI97779 photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement. High Efficiency Light Source: LED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.  High Quality Filters: Improved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error. Greater Light Yield: A focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes. CAL Check Functionality: Hanna*s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.   Large Cuvette Size: The sample cell of the HI97779 fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples. Intuitive Dot Matrix Display: The HI97779 is designed with a backlit, graphic LCD. With virtual keys, a battery status indicator, and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help. Auto-off Protection: The meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life. More Information SKU HI97779-web Product Name Chlorine Dioxide (Rapid) Photometer with CAL Check – HI97779 Quote Required Yes Chlorine Dioxide Range 0.00 to 2.00 mg/L (as ClO2) Chlorine Dioxide Resolution 0.01 mg/L Chlorine Dioxide Accuracy ㊣0.10 mg/L ㊣5% of reading at 25 ∼C Chlorine Dioxide Method adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 4500 ClO2 D Photometer/Colorimeter Light Source LED with 525 nm bandpass filter Photometer/Colorimeter Light Detector silicon photocell Bandpass Filter Bandwidth 8 nm Bandpass Filter Wavelength Accuracy ㊣1.0 nm Cuvette Type round 24.6 mm diameter (22 mm inside) GLP yes Display 128 x 64 pixel B/W LCD with backlight Logging Memory 50 readings Battery Type/Life 1.5 V AA Alkaline (3 pcs.) / > 800 measurements (without backlight) Automatic Shut-Off after 15 minutes of inactivity (30 minutes before a READ measurement) Environment 0 to 50∼C (32 to 122∼F); 0 to 100% RH (IP67) Weight 380 g (13.4 oz.) Dimensions 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0'') Ordering Information HI97738C is supplied with CAL-Check standards, cuvettes (2), caps (2), plastic inserts for cuvette, (2), scissors, cuvette cleaning cloth, 1.5V AA batteries (3), instruction manual, and instrument quality certificate packaged in a rugged, thermoformed, carrying case.   read more
Hanna Instruments (M) Sdn Bhd added new photo in Photometers - Benchtop Photometers
Yesterday at 09:43 am —
HI83399-02 Water & Wastewater Multiparameter (with COD) Photometer and pH meter

HI83399-02 Water & Wastewater Multiparameter (with COD) Photometer and pH meter

RM 7,931.00

HI83399 is a compact, multiparameter photometer for measuring key water and wastewater quality parameters. The meter is one of the most advanced photometers available with a innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. 40 key water and wastewater quality parameters with 73 different methods covering multiple ranges are programmed into the meter. Wastewater treatment digestion parameters include COD, Total Nitrogen and Total Phosphorous which are important for monitoring nutrient removal. The HI83399 also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves. To save valuable laboratory benchtop space, the HI83399 doubles as a professional pH meter with its digital pH/temperature electrode input. Now one meter can be used for both photometric and pH measurements. Advanced optical system Unparalleled performance from a benchtop photometer Digital pH electrode input Save valuable bench space with one meter that works both as a photometer and as a laboratory pH meter Water and Wastewater Treatment Digestion Parameters Allows measurement of COD, Total Nitrogen and Total Phosphorus HI83399 benchtop photometer measures 40 different key water and wastewater quality parameters using 73 different methods that allow for multiple ranges and variations in chemistry for specific applications. The Chemical Oxygen Demand (COD) parameter is included for industrial and municipal wastewater treatment. The Phosphorous and Nitrogen parameters included are beneficial to municipal wastewater treatment customers that need to monitor their biological and chemical nutrient removal process. This photometer features an innovative optical system that uses LEDS, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source ensures accurate and repeatable photometric readings every time. A digital pH electrode input is provided allowing the user to measure pH by a traditional glass electrode. The digital pH electrode has a built in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement. Two USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery. The HI83399 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the 5 wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for education to teach the concept of absorbance by using the Beer-Lambert Law.   Features/Benefits: Backlit 128 x 64 Pixel Graphic LCD Display Backlit graphic display allows for easy viewing in low light conditions The 128 x 64 Pixel LCD allows for a simplified user interface with virtual keys  and on-screen help to guide the user through use of the meter Built-in Reaction Timer for Photometric Measurements The measurement is taken after the countdown timer expires. Countdown timer ensures that all readings are taken at the appropriate reaction intervals regardless of user for better consistency in measurements Absorbance mode Hanna's exclusive CAL Check cuvettes for validation of light source and detector Allows for the user to plot concentration versus absorbance for a specific wavelength for use with user supplied chemistry or for teaching principles of photometry Units of Measure Appropriate unit of measure along with chemical form is displayed along with reading Result Conversion Automatically convert readings to other chemical forms with the touch of a button Cuvette Cover Aids in preventing stray light from affecting measurements Digital pH Electrode Input Measure pH and temperature with a single probe Good Laboratory Practice (GLP) to track calibration information including date, time, buffers used, offset and slope for traceability pH CAL Check alerts user to potential problems during the calibration process Space saving having a pH meter and photometer built into one meter Data Logging Up to 1000 photometric and pH readings can be stored by simply pressing the dedicated LOG button. Logged readings are just as easily recalled by pressing the RCL button Sample ID and User ID information can be added to a logged reading using alphanumeric keypad Connectivity Logged readings can be quickly and easily transferred to a flash drive using the USB-A host port or to a computer using the micro USB-B port Data is exported as a .CSV file for use with common spreadsheet programs Battery Status Indicator Indicates the amount of battery life left Error Messages Photometric error messages include no cap, high zero, and standard too low pH calibration messages include clean electrode, check buffer and check probe On-screen Features Method Selection Users can easily select any one of the 60 measurement methods via the dedicated METHOD button. Data Logging Up to 1000 measurement readings can be logged with user and sample ID and recalled for future use. pH Measurement Mode Selecting the pH measurement mode allows for the photometer to be used as a professional pH meter with many features including temperature compensated measurements, automatic two point calibration, and GLP.   Digestion Parameters Features Cuvette Adapter The HI83399 is supplied with a 16 mm cuvette adapter that accepts digestion vials. Digestion Vial Methods Compatible with COD (EPA, ISO, and mercury free methods), Nitrogen and Phosphorous reagetns packaged in 16 mm digestion vial. Reagents are sold separately. COD Reactor for Digestion Vials A COD reactor is used to heat the digestion vials. The digestion vials must be heated to a specific temperature for a period time making the HI839800 an important accessory required to have a complete wastewater treatment monitoring system.   Advanced Optical System HI83300 is designed with an innovative optical system that incorporates a beam splitter so that light can be used for absorbance readings and for a reference detector. The reference detector monitors the intensity of light and modulates when there is drift due to power fluctuation or the heating of the optical components. Each part has an important role in providing unparalleled performance from a photometer.       High Efficiency LED Light Source An LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components an electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue/violet light output. High Quality Narrow Band Interference Filters The narrow band interference filter not only ensure greater wavelength accuracy (+/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error. Reference Detector for a Stable Light Source A beam splitter is used as part of the internal reference system of the HI83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement. Large Cuvette Size The sample cell of the HI83300 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples. Focusing Lens for Greater Light Yield Adding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.   SKU HI83399-02 Product Name Water & Wastewater Multiparameter (with COD) Photometer and pH meter - HI83399 Quote Required Yes pH Range Photometer pH Resolution Photometer pH Accuracy Photometer pH Calibration Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01) pH Temperature Compensation Automatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used pH CAL Check (electrode diagnostics) clean electrode and check buffer/check probe displayed during calibration pH Method Photometer pH-mV Range ㊣1000 mV pH-mV Resolution 0.1 mV pH-mV Accuracy ㊣0.2 mV Dissolved Oxygen Range 0.0 to 10.0 mg/L (as O2) Dissolved Oxygen Resolution 0.1 mg/L Dissolved Oxygen Accuracy ㊣0.4 mg/L ㊣3% of reading Dissolved Oxygen Measurement Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method Absorbance Range 0.000 to 4.000 Abs Absorbance Resolution 0.001 Abs Absorbance Accuracy +/-0.003Abs @ 1.000 Abs Alkalinity Range Freshwater Alkalinity Resolution 1 mg/L Alkalinity Accuracy ㊣5 mg/L ㊣5% of reading Alkalinity Method Colorimetric method Aluminum Range 0.00 to 1.00 mg/L (as Al3+) Aluminum Resolution 0.01 mg/L Aluminum Accuracy ㊣0.04 mg/L ㊣4% of reading Aluminum Method Adaptation of the aluminon method Ammonia Range Low Range Ammonia Resolution Low and Medium Range Ammonia Accuracy Low Range Ammonia Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method Anionic Surfactants Range 0.00 to 3.50 mg/L (as SDBS) Anionic Surfactants Resolution 0.01 mg/L Anionic Surfactants Accuracy ㊣0.04 mg/L ㊣3% of reading Anionic Surfactants Method Adaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS Bromine Range 0.00 to 8.00 mg/L (as Br2) Bromine Resolution 0.01 mg/L Bromine Accuracy ㊣0.08 mg/L ㊣3% of reading Bromine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method. Calcium Range Freshwater Calcium Resolution 1 mg/L Calcium Accuracy Freshwater Calcium Method Freshwater Chemical Oxygen Demand Range Low Range Chemical Oxygen Demand Resolution 1 mg/L Chemical Oxygen Demand Accuracy Low Range Chemical Oxygen Demand Method Adaptation of the USEPA 410.4 ISO dichromate methods Mercury-free dichromate green method (LR & MR); dichromate method (HR) Chloride Range 0.0 to 20.0 mg/L (as Cl⁻) Chloride Resolution 0.1 mg/L Chloride Accuracy ㊣0.5 mg/L ㊣6% of reading at 25 ∼C Chlorine Dioxide Range 0.00 to 2.00 mg/L (as ClO2) Chlorine Dioxide Resolution 0.01 mg/L Chlorine Dioxide Accuracy ㊣0.10 mg/L ㊣5% of reading Chlorine Dioxide Method Adaptation of the Chlorophenol Red method. Free Chlorine Range 0.00 to 5.00 mg/L (as Cl2) Ultra Low Range Free Chlorine Resolution 0.01 mg/L Ultra Low Range Free Chlorine Accuracy ㊣0.03 mg/L ㊣3% of reading Ultra Low Range Total Chlorine Range 0.00 to 5.00 mg/L (as Cl2) Ultra Low Range Total Chlorine Resolution 0.01 mg/L Ultra Low Range Total Chlorine Accuracy ㊣0.03 mg/L ㊣3% of reading Ultra Low Range Chlorine Method Adaptation of the EPA 330.5 DPD method Free Chlorine (ULR) & Total Chlorine (UHR) Chromium, Hexavalent Range Low Range Chromium, Hexavalent Resolution 1 米g/L Chromium, Hexavalent Accuracy Low Range Chromium, Hexavalent Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide method. Color, Water Range 0 to 500 PCU (Platinum Cobalt Units) Color, Water Resolution 1 PCU Color, Water Accuracy ㊣10 PCU ㊣5% of reading Color, Water Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method. Copper Range Low Range Copper Resolution 0.001 mg/L; 0.01 mg/L Copper Accuracy Low Range Copper Method Adaptation of the EPA bicinchoninate method Cyanuric Acid Range 0 to 80 mg/L (as CYA) Cyanuric Acid Resolution 1 mg/L Cyanuric Acid Accuracy ㊣1 mg/L ㊣15% of reading Cyanuric Acid Method Adaptation of the turbidimetric method Fluoride Range Low Range Fluoride Resolution 0.01 mg/L; 0.1 mg/L Fluoride Accuracy Low Range Fluoride Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method Hardness, Total Range Low Range Hardness, Total Resolution 1 mg/L Hardness, Total Accuracy Low Range Hardness, Total Method Adaptation of the EPA recommended method 130.1 Hardness, Calcium Range 0.00 to 2.70 mg/L (as CaCO3) Hardness, Calcium Resolution 0.01 mg/L Hardness, Calcium Accuracy ㊣0.11 mg/L ㊣5% of reading Hardness, Calcium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method Hardness, Magnesium Range 0.00 to 2.00 mg/L (as CaCO3) Hardness, Magnesium Resolution 0.01 mg/L Hardness, Magnesium Accuracy ㊣0.11 mg/L ㊣5% of reading Hardness, Magnesium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method Hydrazine Range 0 to 400 米g/L (as N2H4) Hydrazine Resolution 1 米g/L Hydrazine Accuracy ㊣4% of full scale reading Hydrazine Method Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88, p-Dimethylaminobenzaldehyde method Iodine Range 0.0 to 12.5 mg/L (as I2) Iodine Resolution 0.1 mg/L Iodine Accuracy ㊣0.1 mg/L ㊣5% of reading Iodine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method Iron Range Low Range Iron Resolution 0.001 mg/L; 0.01 mg/L Iron Accuracy Low Range Iron Method Low Range Magnesium Range 0 to 150 mg/L (as Mg2+) Magnesium Resolution 1 mg/L Magnesium Accuracy ㊣5 mg/L ㊣3% of reading Magnesium Method Adaptation of the Calmagite method Manganese Range Low Range Manganese Resolution 1 米g/L; 0.1 mg/L Manganese Accuracy Low Range Manganese Method Low Range Molybdenum Range 0.0 to 40.0 mg/L (as Mo6+) Molybdenum Resolution 0.1 mg/L Molybdenum Accuracy ㊣0.3 mg/L ㊣5% of reading Molybdenum Method Adaptation of the mercaptoacetic acid method Nickel Range Low Range Nickel Resolution 0.001 mg/L; 0.01 g/L Nickel Accuracy Low range Nickel Method Low Range Nitrate Range 0.0 to 30.0 mg/L (as NO3-- N) 16 mm vial Nitrate Resolution 0.1 mg/L Nitrate Accuracy ㊣0.5 mg/L ㊣10% of reading 16 mm vial Nitrate Method Adaptation of the cadmium reduction method 16 mm vial Nitrite Range Freshwater Low Range Nitrite Resolution Freshwater Nitrite Accuracy Freshwater Low Range Nitrite Method Low Range and Seawater Nitrogen, Total Range Low Range Nitrogen, Total Resolution 0.1 mg/L; 1 mg/L Nitrogen, Total Accuracy Low Range Nitrogen, Total Method Chromotropic acid method Oxygen, Scavenger Range 0 to 1000 米g/L (as DEHA) 0.00 to 1.50 mg/L (as Carbohydrazide) 0.00 to 2.50 mg/L (as Hydroquinone) 0.00 to 4.50 mg/L (as ISO-ascorbic acid) Oxygen, Scavenger Resolution 1 米g/L (DEHA); 0.01 mg/L Oxygen, Scavenger Accuracy ㊣5 米g/L ㊣5% of reading Oxygen, Scavenger Method Adaptation of the iron reduction method Ozone Range 0.00 to 2.00 mg/L (as O3) Ozone Resolution 0.01 mg/L Ozone Accuracy ㊣0.02 mg/L ㊣3% of reading Ozone Method Colorimetric DPD Method Phosphate Range Freshwater Low Range Phosphate Resolution Freshwater Phosphate Accuracy Freshwater Low Range Phosphate Method Freshwater Low Range Phosphorous, Acid Hydrolyzable Range 0.00 to 1.60 mg/L (as P) Phosphorous, Acid Hydrolyzable Resolution 0.01 mg/L Phosphorous, Acid Hydrolyzable Accuracy ㊣0.05 mg/L or ㊣5% of reading Phosphorous, Acid Hydrolyzable Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method Phosphorous, Reactive Range Low Range Phosphorous, Reactive Resolution 0.01 mg/L; 0.1 mg/L Phosphorous, Reactive Accuracy Low Range Phosphorous, Reactive Method Low Range Phosphorous, Total Range Low Range Phosphorous, Total Accuracy Low Range Phosphorous, Total Resolution Low Range Phosphorous, Total Method Low Range Potassium Range 0.0 to 20.0 mg/L (as K) Potassium Resolution 0.1 mg/L Potassium Accuracy ㊣3.0 mg/L ㊣7% of reading Potassium Method Adaptation of the Turbidimetric Tetraphenylborate method Silica Range Low Range Silica Resolution 0.01 mg/L; 1 mg/L Silica Accuracy Low Range Silica Method Low Range Silver Range 0.000 to 1.000 mg/L (as Ag) Silver Resolution 0.001 mg/L Silver Accuracy ㊣0.020 mg/L ㊣5% of reading Silver Method Adaptation of the PAN method Sulfate Range 0 to 150 mg/L (as SO42-) Sulfate Resolution 1 mg/L Sulfate Accuracy ㊣5 mg/L ㊣3% of reading Sulfate Method Turbidimetric - Sulfate is precipitated with barium chloride crystals Zinc Range 0.00 to 3.00 mg/L (as Zn) Zinc Resolution 0.01 mg/L Zinc Accuracy ㊣0.03 mg/L ㊣3% of reading Zinc Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method Input Channels 1 pH electrode input and 5 photometer wavelengths pH Electrode digital pH electrode (not included) Photometer/Colorimeter Light Source 5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters Photometer/Colorimeter Light Detector silicon photodetector Bandpass Filter Bandwidth 8 nm Bandpass Filter Wavelength Accuracy ㊣1 nm Cuvette Type round, 24.6 mm Number of Methods 128 max. GLP calibration data for connected pH electrode Display 128 x 64 pixel LCD with backlight Logging Type log on demand with user name and sample ID optional input Logging Memory 1000 readings Connectivity USB-A host for flash drive; micro-USB-B for power and computer connectivity Power Supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included) Battery Type/Life 3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurement Environment 0 to 50.0 oC (32 to 122.0 oF); 0 to 95% RH, non-condensing Weight 1.0 kg (2.2 lbs.) Dimensions 206 x 177 x 97 mm (8.1 x 7.0 x 3.8'') Ordering Information HI83399 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.   read more
Hanna Instruments (M) Sdn Bhd added new photo in Photometers
Yesterday at 08:35 am —
HI801-02 iris Visible Spectrophotometer

HI801-02 iris Visible Spectrophotometer

RM 16,995.00

                                                                                                            Spectrophotometer with split beam optical system, customizable methods, and rechargeable battery   The iris portable spectrophotometer is unlike any of the products we have created in the past. It is different from our photometers as it allows for measurement in the spectrum of all wavelengths of visible light and not just pre–specified wavelengths. Spectrophotometers work by isolating light at specific wavelengths from white light. This compact meter incorporates a number of features that facilitate both fantastic performance and exceptional usability. Superior design for superior results. iris can test a wide variety of analytical measurements and is capable of measuring in a spectral range of 340 nm to 900 nm. With the compact design of its advanced optical system, iris can be used in almost any sized space while providing accurate and consistent results. The split beam optical system allows iris to automatically compensate for any drift in light source, resulting in superior accuracy.   No need for measurement conversions. Whether you are testing for chlorine or running enzymatic assays, our spectrophotometer will conveniently display results in the units that matter most to you. iris can measure in transmittance, absorbance, and concentration based on your need.   The convenience of pre-programmed methods with the option to expand. iris comes pre-programmed with more than 80 commonly used chemical analysis methods to help you get started. Simply update these methods by connecting to a computer or flash drive. Customize your iris with up to 100 personal methods. iris will guide you through the method creation process step-by-step. For added versatility, each method can include up to 10 calibration points, five different wavelengths, and up to five reaction timers. Easily access your favorite methods directly from the home screen to save time. Built in timers make make measuring seamless. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between measurements and users. If you get stuck, the tutorial mode will walk you through the steps.   Change sample size easily. With our universal cuvette holder and auto-recognition feature, cuvette sizes can be changed when needed. The programmed cuvette size will be displayed on the screen every time you test to ensure that the proper path length is being used by the meter when calculating measurements for correct results.   Round Vial Square   Worry free replacements. iris uses a tungsten-halogen lamp for greater energy efficiency, longer service life, and improved light quality for a wide variety of wavelengths. Replacement lamps are shipped pre-aligned and ready for installation so that you can get back to testing.   Designed for dynamic environments. iris' compact profile and long-lasting battery make it easy to set up anywhere in your lab. The rechargeable lithium ion battery lasts for 3,000 measurements, or 8 hours – well over a full day of use out in the field.     Quality data without the hassle. Export your results with a USB drive or direct PC link organized by sample ID, method, or date range. Save data as a .pdf or .csv for maximum data integrity or flexibility – all without the use of specialized software.   Menu navigation that makes sense. Quickly navigate between screens with custom keys, and access your favorite methods directly from the home screen with our ※favorite methods§ feature.   Sort and share your data. Save data as a .pdf or .csv for maximum data integrity or flexibility. Have the freedom to choose the file format that's best for you. All of your important information is easily visible. With a 6§ display, the screen is large and easy to read. The high contrast makes every character on the display stand out even during outdoor use. The wide viewing angle allows for measurements to be seen from far away, so while working around the lab it is not necessary to hover over the meter to see the measurements.   Zero resistance with a capacitive touch pad. Menu buttons are part of the display. Built to be fully sealed and easy to clean, the meter recognizes key touches even through gloves.   Specification:    More Information SKU HI801-02 Product Name iris Visible Spectrophotometer - HI801 Quote Required Yes pH Range 6.5 to 8.5 pH pH Resolution 0.1 pH pH Accuracy ㊣0.1 pH pH Method Adaptation of the Phenol Red method Dissolved Oxygen Range 0.0 to 10.0 mg/L (as O2 ) Dissolved Oxygen Resolution 0.1 mg/L Dissolved Oxygen Accuracy ㊣0.4 mg/L ㊣3% of reading Dissolved Oxygen Measurement Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method Absorbance Range 0.000 to 3.000 Abs Absorbance Resolution 0.001 Abs Absorbance Accuracy 5 mAbs at 0.000-0.500 Abs 1% at 0.500-3.000 Abs Alkalinity Range 0 to 500 mg/L (as CaCO3 ) Alkalinity Resolution 1 mg/L Alkalinity Accuracy ㊣5 mg/L ㊣5% of reading Alkalinity Method Colorimetric Method Seawater Alkalinity Range 0 to 300 mg/L (as CaCO3 ) Seawater Alkalinity Resolution 1 mg/L Seawater Alkalinity Accuracy ㊣5 mg/L ㊣5% of reading Seawater Alkalinity Method Colorimetric Method Aluminum Range 0.00 to 1.00 mg/L (as Al3+) Aluminum Resolution 0.01 mg/L Aluminum Accuracy ㊣0.04 mg/L ㊣4% of reading Aluminum Method Adaptation of the aluminon method. Ammonia Range Low Range Ammonia Resolution Low and Medium Range Ammonia Accuracy Low Range Ammonia Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler method. Anionic Surfactants Range 0.00 to 3.50 mg/L (as SDBS) Anionic Surfactants Resolution 0.01 mg/L Anionic Surfactants Accuracy ㊣0.04 mg/L ㊣3% of reading Anionic Surfactants Method Adaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS Bromine Range 0.00 to 8.00 mg/L (as Br2 ) Bromine Resolution 0.01 mg/L Bromine Accuracy ㊣0.08 mg/L ㊣3% of reading Bromine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method Calcium Range 0 to 400 mg/L (as Ca2+) Calcium Resolution 1 mg/L Calcium Accuracy ㊣10 mg/L ㊣5% of reading Calcium Method Adaptation of the Oxalate method Carbon Dioxide Range 0.00 to 2.00 mg/L (as ClO2 ) Carbon Dioxide Resolution 0.01 mg/L Carbon Dioxide Accuracy ㊣0.10 mg/L ㊣5% of reading Carbon Dioxide Method Adaptation of the Chlorophenol Red method Chemical Oxygen Demand Range Low Range Chemical Oxygen Demand Resolution 1 mg/L Chemical Oxygen Demand Accuracy Low Range Chemical Oxygen Demand Method Adaptation of the USEPA 410.4 Chloride Range 0.0 to 20.0 mg/L (as Cl) Chloride Resolution 0.1 mg/L Chloride Accuracy ㊣0.5 mg/L ㊣6% of reading Chloride Method Adaptation of the mercury(II) thiocyanate method Chlorine Dioxide Range 0.00 to 2.00 mg/L (as ClO2 ) Chlorine Dioxide Resolution 0.01 mg/L Chlorine Dioxide Accuracy ㊣0.10 mg/L ㊣5% of reading Chlorine Dioxide Method Adaptation of the Chlorophenol Red method Free Chlorine Range Ultra Low Range Free Chlorine Resolution Ultra Low Range Free Chlorine Accuracy Ultra Low Range Total Chlorine Range Ultra Low Range Total Chlorine Resolution Ultra Low Range Total Chlorine Accuracy Ultra Low Range Chromium, Hexavalent Range Low Range Chromium, Hexavalent Resolution Low Range Chromium, Hexavalent Accuracy Low Range Chromium, Hexavalent Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687, Diphenylcarbohydrazide method Color, Water Range 0 to 500 PCU (Platinum Cobalt Units) Color, Water Resolution 1 PCU Color, Water Accuracy ㊣10 PCU ㊣5% of reading Color, Water Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method Color, Maple Syrup Range 0.00 to 100.00 %T Color, Maple Syrup Resolution 0.01 %T Color, Maple Syrup Accuracy ㊣3% of reading Color, Maple Syrup Method Direct measure Copper Range Low Range Copper Resolution Low Range Copper Accuracy Low Range Copper Method Adaptation of the EPA method Cyanide Range 0.000 to 0.200 mg/L (as CN-) Cyanide Resolution 0.001 mg/L Cyanide Accuracy ㊣0.005 mg/L ㊣3% of reading Cyanide Method Pyridine-Pyrazalone Cyanuric Acid Range 0 to 100 mg/L (as CYA) Cyanuric Acid Resolution 1 mg/L Cyanuric Acid Accuracy ㊣1 mg/L ㊣15% of reading Cyanuric Acid Method Adaptation of the turbidimetric method Fluoride Range Low Range Fluoride Resolution Low Range Fluoride Accuracy Low Range Fluoride Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method Hardness, Total Range Low Range Hardness, Total Resolution 1 mg/L Hardness, Total Accuracy Low Range Hardness, Total Method Adaptation of the EPA recommended method 130.1 Hardness, Calcium Range 0.00 to 2.70 mg/L (as CaCO3 ) Hardness, Calcium Resolution 0.01 mg/L Hardness, Calcium Accuracy ㊣0.11 mg/L ㊣5% of reading Hardness, Calcium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method Hardness, Magnesium Range 0.00 to 2.00 mg/L (CaCO3 ) Hardness, Magnesium Resolution 0.01 mg/L Hardness, Magnesium Accuracy ㊣0.11 mg/L ㊣5% of reading Hardness, Magnesium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method Hydrazine Range 0 to 400 µg/L (as N2H4 ) Hydrazine Resolution 1 µg/L Hydrazine Accuracy ㊣4% of full scale reading Hydrazine Method Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385, p-Dimethylaminobenzaldehyde method Iodine Range 0.0 to 12.5 mg/L (as I2 ) Iodine Resolution 0.1 mg/L Iodine Accuracy ㊣0.1 mg/L ㊣5% of reading Iodine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method Iron Range Low Range Iron Resolution Low Range Iron Accuracy Low Range Iron Method Low Range Magnesium Range 0 to 150 mg/L (as Mg2+) Magnesium Resolution 1 mg/L Magnesium Accuracy ㊣5 mg/L ㊣3% of reading Magnesium Method Adaptation of the Calmagite method Manganese Range Low Range Manganese Resolution Low Range Manganese Accuracy Low Range Manganese Method Low Range Molybdenum Range 0.0 to 40.0 mg/L (as Mo6+) Molybdenum Resolution 0.1 mg/L Molybdenum Accuracy ㊣0.3 mg/L ㊣5% of reading Molybdenum Method Adaptation of the mercaptoacetic acid method Nickel Range Low Range Nickel Resolution Low Range Nickel Accuracy Low Range Nickel Method Low Range Nitrate Range 0.0 to 30.0 mg/L (as NO3 - N) Chromotropic Acid Nitrate Resolution 0.1 mg/L Nitrate Accuracy ㊣0.5 mg/L ㊣10% of reading Chromotropic Acid Nitrate Method Adaptation of the cadmium reduction method Chromotropic Acid Nitrite Range Marine Ultra Low Range Nitrite Resolution Marine Ultra Low Range Nitrite Accuracy Marine Ultra Low Range Nitrite Method Marine Ultra Low Range Nitrogen, Total Range Low Range Nitrogen, Total Resolution Low Range Nitrogen, Total Accuracy Low Range Nitrogen, Total Method Chromotropic acid method Oxygen, Scavenger Range Carbohydrazide Oxygen, Scavenger Resolution Carbohydrazide Oxygen, Scavenger Accuracy Carbohydrazide Oxygen, Scavenger Method Adaptation of the iron reduction method Ozone Range 0.00 to 2.00 mg/L (as O3 ) Ozone Resolution 0.01 mg/L Ozone Accuracy ㊣0.02 mg/L ㊣3% of reading Ozone Method Colorimetric DPD Method Phosphate Range Low Range Phosphate Resolution Low Range Phosphate Accuracy Low Range Phosphate Method Low Range Phosphorous, Acid Hydrolyzable Range 0.00 to 1.60 mg/L (as P) Phosphorous, Acid Hydrolyzable Resolution 0.01 mg/L Phosphorous, Acid Hydrolyzable Accuracy ㊣0.05 mg/L or ㊣5% of reading Phosphorous, Acid Hydrolyzable Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method. Phosphorous, Reactive Range Low Range Phosphorous, Reactive Resolution Low Range Phosphorous, Reactive Accuracy Low Range Phosphorous, Reactive Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method. Phosphorous, Total Range Low Range Phosphorous, Total Accuracy Low Range Phosphorous, Total Resolution Low Range Phosphorous, Total Method Low Range Potassium Range Low Range Potassium Resolution Low Range Potassium Accuracy Low Range Potassium Method Adaptation of the Turbidimetric Tetraphenylborate method Silica Range Low Range Silica Resolution Low Range Silica Accuracy Low Range Silica Method Low Range Silver Range 0.000 to 1.000 mg/L (as Ag) Silver Resolution 0.001 mg/L Silver Accuracy ㊣0.020 mg/L ㊣5% of reading Silver Method Adaptation of the PAN method Sulfate Range 0 to 150 mg/L (as SO42-) Sulfate Resolution 1 mg/L Sulfate Accuracy ㊣5 mg/L ㊣3% of reading Sulfate Method Sulfate is precipitated with barium chloride crystals Zinc Range 0.00 to 3.00 mg/L (as Zn) Zinc Resolution 0.01 mg/L Zinc Accuracy ㊣0.03 mg/L ㊣3% of reading Zinc Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method Wavelength Range 340 to 900 nm Wavelength Resolution 1 nm Wavelength Accuracy ㊣1.5 nm Measurement Modes Transmittance (% T), absorbance (abs), concentration with choice of units (ppm, mg/L, ppt, ºf, ºe, ppb, meq/L, 米g/L, PCU, Pfund, pH, dKH, ºdH, meq/kg or no measurement unit) Wavelength Selection automatic, based on the selected method (editable for user methods only) Optical System split beam sample and reference light detectors Wavelength Calibration internal, automatic at power-on, visual feedback Data Points Stored up to 9999 measured values Export Capability .csv file format, .pdf file format Connectivity (1) USB - A (mass storage host); (1) USB - B (mass storage device) Power Supply 15 VDC power adapter; 10.8 VDC Li-Ion rechargeable battery Battery Type/Life 3000 measurements or 8 hours Environment 0 to 50 ∼C (32 to 122 ∼F); 0 to 95% RH Weight 3 kg (6.6 lbs) Dimensions 155 x 205 x 322 mm (6.1 x 8.0 x 12.6'') Ordering Information HI801 is supplied with 22 mm sample cuvette and cap (4), 10 mm square, 13 mm round and 16 mm round cuvette adapters, cloth for wiping cuvettes, scissors, USB cable, lithium ion rechargeable battery, 115VAC to 15VDC power adapter, USB drive, instruction manual, and instrument quality certificate.   read more
Hanna Instruments (M) Sdn Bhd added new photo in Monitors & Dataloggers
Yesterday at 08:22 am —
HI146-00 Pronto Water-resistant Wall-Mounted Precision Thermometer (∼C)

HI146-00 Pronto Water-resistant Wall-Mounted Precision Thermometer (∼C)

RM 488.00

The HI146-00 is a high accuracy thermometer with a professional grade probe attached to a flexible 2 m (6.6*) cable. Monitor the exact temperature of any product continuously and easily observe it on the LCD display. CAL Check™ feature to confirm that the thermometer is working correctly. Meets HAACP requirements. Ideal for monitoring the temperatures of liquids, semi-solids, and refrigerated foods. Details The HI146-00 is a high accuracy thermometer with a professional grade probe and a flexible 2 m cable. The CAL CHECK® feature is incorporated into its function to allow you to confirm the accuracy of the meters any time. You can monitor the exact temperature of any product continuously and easily observe it on the LCD display. HI-146-00 can be easily carried from station to station or installed in a fixed position using the moulded eye and a wall mount probe holder. With its compact and simplified design featuring a fixed stainless steel probe and optional probe holder, this thermometer is ideal for monitoring the temperatures of liquids, semi-solids and refrigerated foods. Key features HACCP compliant CAL CHECK® feature Stainless steel temperature probe Water resistant SKU HI146-00 Product Name Pronto Water-resistant Wall-Mounted Precision Thermometer (∼C) HI146-00 Quote Required Yes Temperature Range -50.0 to 150.0∼C Temperature Resolution 0.1∼C Temperature Accuracy ㊣0.3∼C (-20 to 90∼C); ㊣0.5∼C (outside) Temperature Probe stainless steel probe (fixed) with 2 m (6.6*) cable; 160 x dia 3 mm (6.3 x dia 0.1**) Battery Type/Life 1.5V AA / approximately 5 years Environment IP54; 0 to 50∼C (32 to 122∼F); RH max 95% Dimensions 86 x 110 x 43 mm (3.4 x 4.3 x 1.7**) Weight 150 Ordering Information HI146-00 (Pronto) is supplied with stainless steel temperature probe, battery and instructions. Probe Type (sensor) stainless steel probe (fixed) with 2 m (6.6*) cable; 160 x dia 3 mm (6.3 x dia 0.1**) read more
Hanna Instruments (M) Sdn Bhd added new photo in Monitors & Dataloggers
May 3, 2024 at 02:17 pm —
HI147-00 Checkfridge™ Remote Sensor Thermometer

HI147-00 Checkfridge™ Remote Sensor Thermometer

RM 352.00

The HI147 is a remote temperature sensor ideal for monitoring in food care environments. It contains magnets for easy placement on a metal surface and delivers high accuracy measurements over a wide temperature range. CAL Check™ Magnetized Clear Display The HI147 is a remote temperature ideal for monitoring in food care environments. It contains magnets for easy placement on a metal surface and delivers high accuracy measurements over a wide temperature range. The thermometer*s unique CAL Check™ feature allows for an internal calibration of the device with the flick of a switch, thereby alleviating the time preparing an ice bath.   Features at-a-glance CAL Check™  - The thermometer*s unique CAL Check™ feature allows for an internal calibration of the device with the flick of a switch, thereby alleviating the time preparing an ice bath. Magnetized - Two magnets located on the back of the device all for easy placement on the outside of a refrigerator or metal cabinet. Food Compatible Cable - The thermometer is specially designed with a food compatible cable for continuous monitoring of temperature in food care environments.   SKU HI147-web Product Name Checkfridge™ Remote Sensor Thermometer - HI147 Quote Required Yes Temperature Range HI147-00 -50.0 to 150.0∼C HI147-01 -58.0 to 302.0∼F Temperature Resolution HI147-00 0.1∼C HI147-01 0.1∼F (-58.0 to 199.9∼F) 1∼F (200 to 302∼F) Temperature Accuracy HI147-00 ㊣0.3∼C (-20 to 90∼C); ㊣0.5∼C (outside) HI147-01 ㊣0.6∼F (-4 to 194∼F); ㊣1∼F (outside) Battery Type/Life 1.5V AAA / approximately 3 years of continuous use Environment 0 to 50∼C (32 to 122∼F); RH max 95% Dimensions 93 x 39 x 31 mm (3.7 x 1.5 x 1.2**) Weight 60 g (2.1 oz.) Ordering Information HI147 is supplied with battery and instructions.   read more
Hanna Instruments (M) Sdn Bhd added 2 new photos in Benchtop Meters - Oxygen, Dissolved
May 3, 2024 at 01:45 pm —
HI6421P Advanced Dissolved Oxygen Benchtop Meter with Polarographic DO Probe
HI6421 Advanced Dissolved Oxygen Benchtop Meter with Optical DO Probe (opdo®)
Hanna Instruments (M) Sdn Bhd added new photo in Benchtop Meters - EC/TDS/Salinity
May 3, 2024 at 01:33 pm —
HI6321 Advanced Conductivity Benchtop Meter

HI6321 Advanced Conductivity Benchtop Meter

RM 5,807.00

HI6321 is a streamlined Conductivity/Resistivity/TDS/Salinity/Temperature benchtop meter with a large touch screen display, comprised of a housing and an integrated conductivity measurement module. HI6321 is a streamlined Conductivity/Resistivity/TDS/Salinity/Temperature benchtop meter with a large touch screen display, comprised of a housing and an integrated conductivity measurement module. Compact and easy to operate, the HI6321 includes Hanna*s HI7631233 four-ring conductivity/ resistivity/TDS/salinity probe. Recommended for a wide range of industrial process water applications, HI7631233 provides stable measurements over a wide measurement range and does not require frequent calibrations. An integral temperature sensor measures the process temperature and adjusts the measured conductivity to a reference temperature by applying specialized compensation algorithms: Linear: appropriate when it is assumed that the temperature coefficient of variation has the same value for all measurement temperatures. Standard: appropriate for high-purity water measurements and documented in ASTM Standard D5391-14. This setting should be used for >1Mohm.cm resistivity measurements. Natural: appropriate for natural ground, well, or surface water (or water with similar composition) in accordance with ISO7888 standard. The result is reliable electrolytic conductivity (EC), TDS (Total Dissolved Solids), resistivity, or Seawater Salinity in percent, psu, or ppt units. TDS is a calculated value based on the conductivity of the solution (TDS = factor x EC25). A TDS factor is a conversion factor used to change an EC measurement to a ppm measurement. Sal psu: The practical salinity of seawater relates the ratio of electrical conductivity of a normal seawater sample at 15 ∼C and 1 atmosphere to a potassium chloride solution (KCl) with a mass of 32.4356 g/Kg water at the same temperature and pressure. Under these conditions the ratio is equal to 1 and S=35. The practical salinity scale may be applied to values 0 through 42.00 psu at temperatures between 0 to 35 ∼C. Sal ppt: measurements expressed in ppt are based on the Natural Seawater Scale that extends from 0.00 to 80.00 g/L and covers 10 to 31 ∼C temperature range. It determines the salinity based upon a conductivity ratio of sample to standard seawater at 15 ∼C and an approximate salinity value of 35 in seawater. Sal %: in this scale 100% salinity is equivalent to roughly 10% solids. User interface 7-inch capacitive touch screen with multi-touch support Capacitive touch back, home and system menu keys User-friendly icons and symbols allow users to easily navigate and interpret the instrument functions. The user can select between five different views: Basic measurement configuration Simple GLP with calibration information Full GLP with electrode status and calibration point details Live updated, interactive graph Tabulated data with date, time, and notes Measurement Measure 米S/cm, mS/cm (Conductivity); 次·cm, k次·cm, M次·cm (Resistivity); ppm, ppt (TDS); ppt, PSU, % (Salinity) with temperature Application-specific profiles allow quick and direct measurement without the need to update the sensor and system settings Active log during measurement o Measurement stability indicator (using the Stability Criteria setting) Reading modes: direct and direct/autohold Temperature compensation can be Automatic or set manually Audible and/or alarm messages for measurements outside of predefined limits Galvanic isolation for conductivity measurement Calibration Standard single point salinity calibration in 100% salinity standard, with the reading salinity scale set to % Standard single or multiple conductivity calibration with standards Non-volatile memory saves data and settings Logging Data log collection of at least 1,000,000 data points (with time and date stamp) Logging types: manual, automatic, autohold Sample ID for manual and Autohold data Connectivity features & services Transfer logged data to a USB thumb drive Log files that include measurements and calibration data (as .csv file) FTP and email for log export via Ethernet and Wi-Fi connection o USB type A for USB stick, keyboard, and printer USB type C for USB stick and PC connection SKU HI6321 Product Name Advanced Conductivity Benchtop Meter - HI6321 Quote Required Yes Conductivity Range 0.000 to 9.999 米S/cm; 10.00 to 99.99 米S/cm; 100.0 to 999.9 米S/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm Conductivity Resolution 0.001 米S/cm; 0.01 米S/cm; 0.1 米S/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm Conductivity Accuracy ㊣1 % of reading (㊣0.01 米S/cm) Resistivity Range 1.0 to 99.9 次·cm; 100 to 999 次·cm; 1.00 to 9.99 K次·cm; 10.0 to 99.9 K次·cm; 100 to 999 K次·cm; 1.00 to 9.99 M次·cm; 10.0 to 100.0 M次·cm Resistivity Resolution 0.1 次·cm; 1 次·cm; 0.01 K次·cm; 0.1 K次·cm; 1 K次·cm; 0.01 M次·cm; 0.1 M次·cm Resistivity Accuracy ㊣1 % of reading (㊣1 次·cm) Total Dissolved Solids (TDS) Range 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor) Total Dissolved Solids (TDS) Resolution 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt Total Dissolved Solids (TDS) Accuracy ㊣1 % of reading (㊣0.01 ppm) Salinity Range 0.00 to 42.00 PSU - Practical Scale 0.00 to 80.00 ppt - Natural Sea Water 0.0 to 400.0 % - Percent Scale Salinity Resolution 0.01 for Practical Scale / Natural Sea Water 0.1 % for Percent Scale Salinity Accuracy ㊣1 % of reading Temperature Range −20.0 to 120.0 ∼C −4.0 to 248.0 ∼F 253.0 to 393.0 K Temperature Resolution 0.1 ∼C; 0.1 ∼F; 0.1 K Temperature Accuracy ㊣0.2 ∼C; ㊣0.4 ∼F; ㊣0.2 K Conductivity Calibration points Auto standard recognition / User standard, Single Point / Multi Point calibration Conductivity Calibration Standard solutions 84.00 µS/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00 mS/cm, 111.8 mS/cm Conductivity Calibration Reminder Disabled Daily Salinity Calibration 1 point for Percent Scale Temperature Compensation Automatic or Manual Reading Modes Direct Direct/Autohold Reading Stability criteria Accurate Medium Fast Reading Sampling rate 1000 ms EC Views Basic Measurement (EC, Resistivity, TDS, Salinity, Temperature) Stability status EC Views Simple GLP Basic view information Last calibration date, offset EC Views Full GLP Simple GLP information and calibration point details EC Views Table Measurements updated every second are displayed in table EC Views Graph (Plot) Measurement versus time graph can be panned or zoomed (pinch-to-zoom technology) Logging Type Automatic, Manual, Autohold Logging Number of records 50 000 maximum per file Stores at least 1 000 000 data points per user Logging Automatic interval 1, 2, 5, 10, 30 seconds 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes Logging Sample ID Incremental mode Logging Export option .csv file format Users Up to 9 users and the default administrator account Connectivity USB-A 2 ports for keyboard input or USB thumb drive Connectivity USB-C 1 port for PC connectivity and USB-C type thumb drive Connectivity Wi-Fi & Ethernet FTP Web server Log transfer and download Email Connectivity RS232 Connecting peripherals Power supply DC adapter 100-240AC to 24VDC 2.5A Environment 0 - 50 ∼C / 32 - 122 ∼F / 273 - 323 K maximum 95% RH non-condensing Dimensions 205 x 160 x 77 mm (8.0 x 6.2 x 3.0 ※) Weight Approximately 1.2 kg (26.5 lbs.) read more
Hanna Instruments (M) Sdn Bhd added new photo in Benchtop Meters - pH/ORP
May 3, 2024 at 01:08 pm —
HI3220 pH/ORP/Temperature Bench Meter with Calibration Check

HI3220 pH/ORP/Temperature Bench Meter with Calibration Check

RM 2,323.00

HI3220 is a professional pH bench meter with a graphic LCD designed to provide high accuracy and ease of use both in the laboratory as well as in harsh industrial conditions. This instruments is a single input model measuring pH, ORP, and temperature utilizing a single channel. A Relative mV feature is also available. Main Features: Single input channel Up to 5 point pH calibration with 7 standard buffers and 5 custom buffers to choose from Messages on the graphic LCD for an easy and accurate calibration Diagnostic features to alert the user when the electrode needs cleaning Three types of logging modes (for pH and mV) Stability logging Interval logging Log-on-demand Relative mV measurements Log on demand up to 200 samples Log interval with log on stability feature up to 600 records Auto Hold feature, to freeze first stable reading on the LCD GLP feature, to view last calibration data for pH or Rel mV PC Interface More Information SKU HI3220 Product Name pH/ORP/Temperature Bench Meter with Calibration Check - HI3220 Quote Required Yes pH Range -2.0 to 20.0 pH / -2.00 to 20.00 pH / -2.000 to 20.000 pH pH Resolution 0.1 pH / 0.01 pH / 0.001 pH pH Accuracy ㊣0.01 pH / ㊣0.002 pH pH Calibration Up to 5 points / 7 standard buffers (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) / 5 custom buffers ORP Range ㊣2000.0 mV ORP Resolution 0.1 mV ORP Accuracy ㊣0.2 mV Temperature Range -20.0 to 120.0 ∼C (-4.0 to 248.0 ∼F) Temperature Resolution 0.1 ∼C (0.1 ∼F) Temperature Accuracy ㊣0.2 ∼C (㊣0.4 ∼F) (excluding probe error) Rel mV offset range ㊣2000 mV Slope calibration From 80 to 110% Temperature compensation Manual / Automatic Electrode Hanna BNC connection pH / ORP electrodes Temperature probe RCA Connection / Recommended option LOG on demand 200 samples Lot logging 5, 10, 30 seconds / 1, 2, 5, 10, 15, 30, 60, 120, 180 minutes / AutoEnd (maximum 600 samples) Environment 0 to 50 ∼C (32 to 122 ∼F) / max. RH 55% non-condensing Power Supply 12 Vdc power adapter PC interface opto-isolated USB Dimensions 235 x 207 x 110 mm (9.2 x 8.14 x 4.33 in.) Weight(meter only) 1.8 Kg (4.1 lbs)   read more
Hanna Instruments (M) Sdn Bhd added new photo in Benchtop Meters - ISE
May 3, 2024 at 12:28 pm —
HI5522-02 Laboratory Research Grade Benchtop pH/mV/ISE and EC/TDS/Salinity/Resistivity Meter

HI5522-02 Laboratory Research Grade Benchtop pH/mV/ISE and EC/TDS/Salinity/Resistivity Meter

RM 6,742.00

The HI5522 is an advanced research grade benchtop pH/mV/ISE/EC/TDS/Salinity/Resistivity meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity. The HI5522 is rich in features including ISE incremental methods, data logging, alarm limits, comprehensive GLP, and many more while retaining simplicity in use with both dedicated key for routine operation and virtual keys that guide the user through setup options. The HI5522 ensures confidence in pH measurements with the exclusive Hanna Instruments CAL Check™ feature that alerts the user to potential problems during calibration including if the buffer is contaminated or the probe needs to be cleaned. Capacitive touch keypad Two independent channels ISE choice of concentration units and incremental methods The HI5522 is an advanced research grade benchtop pH/ORP/ISE and EC/TDS/Salinity/Resistivity meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity. The HI5522 is a two-channel meter that allows for simultaneous measure of pH, ORP, or ISE on one channel and EC, TDS, Salinity, or Resistivity on the other.  Channel 1 has a BNC connection for use with the expansive line of pH, ORP, and ISE electrodes that Hanna Instruments offers. The meter is supplied with the HI1131B glass body, double junction, combination pH electrode that operates over a wide temperature range from 0 to 100 ∼C.   All readings are automatically compensated for temperature variations with the separate HI7662-T temperature probe or from the built in temperature sensor of the conductivity probe on Channel 2.  The HI5522 is supplied with the HI76312 four-ring conductivity probe that operates over a wide range from 0.000 米S/cm to 1000.0 mS/cm*. The meter can be set to auto-ranging in which the meter chooses the appropriate conductivity range from seven ranges or fixed range in which the meter will only display reading in 米S/cm or mS/cm.  All readings are automatically compensated for temperature variations with a built in temperature sensor. The temperature correction coefficient is adjustable from 0.00 to 10.00 %/∼C. As a pH meter the HI5522 can be calibrated up to five points with a choice of eight pre-programmed buffers or five custom buffers. The HI5522 features Hanna*s exclusive CAL Check™ to alert the user of potential problems during the pH calibration process.  Indicators displayed during calibration include ※Electrode Dirty/Broken§ and ※Buffer Contaminated.§ The overall probe condition based on the offset and slope characteristic of the electrode is displayed as a percentage after calibration is complete. In ISE mode the HI5522 can be calibrated up to five points with a choice of five fixed standards or five user defined in any concentration unit. The calibration data including date, time, standards used and slope can be viewed at any time along with the current measurement by selecting the Good Laboratory Practice (GLP) display option. As an EC/TDS/Salinity/Resistivity meter the HI5522 can be calibrated up to four points with a choice of six pre-programmed conductivity standards or user defined custom standards. Resistivity, TDS, Practical Salinity (PSU) and Natural Seawater Scale are calibrated through conductivity. The % NaCl is calibrated to single point with the HI7037 salinity standard. The calibration data including date, time, and standards used, offset and cell factor can be accessed at any time along with the current measurement by selecting the Good Laboratory Practice (GLP) display option. For the measurement of high purity water used in pharmaceutical manufacturing, the HI5522 is programmed with the three stages of the USP <645> method.  Once a stage is met a report is generated and can be saved. Up to 200 reports can be stored and transferred to a Windows® compatible computer using a USB cable and software (sold separately). Three selectable logging modes are available: automatic, manual and AutoHold logging. Up to 100,000 data points can be recorded in 100 lots with 50,000 records max/lot on each channel and exported to a computer for data review and storage.   Features at-a-glance Highly Customizable User Interface – The user interface of the HI5522 allows the user to show measurements in various modes: basic measurement with or without GLP information, real-time graphing, and logging data. Calibration stability criteria can be adjusted from fast, moderate, and accurate. Programmable alarm limits can be set to inside or outside allowable limits. Color Graphic LCD – The HI5522 features a color graphic LCD with on-screen help, graphic, and custom color configurations. The display allows for real-time graphing and the use of virtual keys provide for an intuitive user interface. Capacitive Touch – The HI5522 features sensitive capacitive touch buttons for accurate keystrokes when navigating menus and screens. There are four dedicated keys that are used for routine operations including calibration and switching measurement modes and four virtual keys that change based upon use. The capacitive touch technology ensures the buttons never get clogged with sample residue. Four Ring Conductivity Probe – All readings are performed with the HI76312 four-ring conductivity probe that has a built in temperature sensor for automatic temperature correction.  The four rings are made with platinum and the body of the electrode is made of Polyetherimide (PEI) plastic that is resistant to many harsh chemicals.  The four-ring design allows for this probe to be used over a wide range of measurements. Choice of Calibration – Automatic buffer recognition, semiautomatic, and direct manual entry pH calibration options are available for calibrating up to five points, from a selection of eight standard buffers and up to five custom buffers.  For the conductivity channel the calibration can be set to automatic standard recognition or user entry along with a choice of single or multi-point. Calibration can be performed up to four points when multi-point is selected. CAL Check™ – CAL Check™ alerts users to potential problems during the calibration of the pH electrode. Indicators include ※Electrode Dirty/Broken,§ ※Buffer Contaminated,§ electrode response timeand the overall probe condition as a percentage that is based on the offset and slope characteristics. GLP Data – HI5522 includes a GLP Feature thatallows users to view calibration data and calibration expiration information at the touch of a key. Calibration data include date, time, standards used for calibration. ISE Measurement with Choice of Concentration Units – The HI5522 allows for calibration and readings in choice of concentration units. The choices of concentration units include ppt, g/L, mg/mL, ppm, mg/L, 米g/L, ppb, 米g/L, mg/mL, M, mol/L, mmol/L, %w/v and a user-defined unit. ISE Measurement with Incremental Methods – The known addition, known subtraction, analyte addition, and analyte subtraction incremental methods are pre-programmed into the HI5522.  Simply follow the on screen guided procedure and the meter will perform the calculation automatically allowing for a higher level of accuracy to be obtained as compared to a direct ISE measurement. Data Logging – Three selectable logging modes are available on the HI5522: automatic, manual, and AutoHold logging. Automatic and manual logs up to 100 lots with 50,000 records max/lot, with up to 100,000 total data points. Automatic logging features the option to save data according to sampling period and interval. Data Transfer – Data can be transferred to a PC with USB cable and HI92000 software (both sold separately). Contextual Help – Contextual help is always available through a dedicated ※HELP§ key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration.  The help information displayed is relative to the setting/option being viewed. CAL Check alert to potential problems during calibration Comprehensive GLP Data Real time logging   More Information SKU HI5522-02 Product Name Laboratory Research Grade Benchtop pH/mV/ISE and EC/TDS/Salinity/Resistivity Meter - HI5522 Quote Required Yes pH Range -2.0 to 20.0 pH / -2.00 to 20.00 pH / -2.000 to 20.000 pH pH Resolution 0.1 pH / 0.01 pH / 0.001 pH pH Accuracy ㊣0.1 pH / ㊣0.01 pH / ㊣0.002 pH ㊣ 1LSD pH Calibration Up to five-point calibration, eight standard buffers available (pH 1.68, 3.00, 4.01, 6.86, 7.01,9.18, 10.01, 12.45), and five custom buffers pH Temperature Compensation automatic or manual from -20.0 to 120.0 ∼C mV Range ㊣2000.0 mV mV Resolution 0.1 mV mV Accuracy ㊣0.2 mV ㊣ 1LSD mV Relative Offset ㊣2000.0 mV ISE Range e.g. 10-7 to 10M/ 0.005 to 105 ppm/ 5·10–7 to 5·107 conc ISE Resolution 1 conc./ 0.1 conc. / 0.01 conc. / 0.001 conc ISE Accuracy ㊣0.5% (monovalent ions); ㊣1% (divalent ions) ISE Calibration Up to five-point calibration, seven fixed standard solutions available for each measurement unit, and five custom solutions EC Range 0.000 to 9.999 米S/cm, 10.00 to 99.99 米S/cm, 100.0 to 999.9 米S/cm, 1.000 to 9.999 mS/cm, 10.00 to 99.99 mS/cm, 100.0 to 1000.0 mS/cm actual EC* EC Resolution 0.001 米S/cm, 0.01 米S/cm, 0.1 米S/cm, 1 米S/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm EC Accuracy ㊣1% of reading (㊣0.01 米S/cm) EC Calibration automatic standard recognition (0.000 米S/cm, 84.00 米S/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00 mS/cm, 111.8 mS/cm) or user standard; single point or multi-point calibration TDS Range 0.000 to 9.999 ppm, 10.00 to 99.99 ppm, 100.0 to 999.9 ppm, 1.000 to 9.999 ppt, 10.00 to 99.99 ppt, 100.0 to 400.0 ppt actual TDS* (with 1.00 factor) TDS Resolution 0.001 ppm, 0.01 ppm, 0.1 ppm, 1 ppm, 0.001 ppt, 0.01 ppt, 0.1 ppt TDS Accuracy ㊣1% of reading (㊣0.01 ppm) EC/TDS Temperature Compensation Disabled / Linear / Non linear (natural water) Temperature Correction Coefficient 0.00 to 10.00 %/∼C Reference Temperature 5.0 ∼C to 30.0 ∼C Cell Constant 0.0500 to 200.00 Cell Type 4 cells Salinity (% NaCl) Range 0.0 to 400.0% Salinity (% NaCl) Resolution 0.01% Salinity (% NaCl) Accuracy ㊣1% of reading Salinity (PSU) Range 0.00 to 42.00 psu Salinity (PSU) Resolution 0.01 Salinity (PSU) Accuracy ㊣1% of reading Salinity (PSU) Calibration one-point (with HI7037 standard) Salinity Range 0.00 to 80.00 ppt Salinity Resolution (ppt) 0.01 Salinity Accuracy (ppt) ㊣1% of reading Resistivity Range 1.0 to 99.9 次•cm; 100 to 999 次•cm; 1.00 to 9.99 K次•cm; 10.0 to 99.9 K次•cm; 100 to 999 K次•cm; 1.00 to 9.99 M次•cm; 10.0 to 100.0 M次•cm Resistivity Resolution 0.1 次•cm; 1 次•cm; 0.01 K次•cm; 0.1 K次•cm; 1 K次•cm; 0.01 M次•cm; 0.1 M次•cm* Resistivity Accuracy ㊣2% of reading (㊣1 次•cm) Temperature Range -20.0 to 120.0 ºC**; -4.0 to 248.0 ºF**; 253.15 to 393.15 K** Temperature Resolution 0.1 ∼C, 0.1 ∼F, 0.1 K Temperature Accuracy ㊣0.2 ∼C; ㊣0.4 ∼F; ㊣0.2 K (without probe) Input Channels 2 (pH/mV/ISE; Conductivity/Resistivity/TDS/ Salinity) pH Electrode HI1131B glass body pH electrode with BNC connector and 1 m (3.3*) cable (included) EC/TDS Probe HI76312 platinum, four-ring EC/TDS probe with and 1 m (3.3*) cable (included) Temperature Probe HI7662-T stainless steel temperature probe with 1 m (3.3*) cable (included) Logging Type Automatic, Manual, AutoHold Logging Memory Up to 100 lots, 50,000 records max/lot; maximum 100,000 data points / channel Logging Interval 14 selectable between 1 second and 180 minutes Connectivity Opto-isolated USB GLP yes (GLP Channel 1 Calibration Timeout Reminder yes USP Compliant USP <645> Application Profiles Up to 10 (5 for each) Display Color Graphic LCD 240 x 320 pixels, 8 keys capacitive touch keyboard Power Supply 12 VDC adapter (included) Environment 0 to 50∼C (32 to 122∼F; 273 to 323 K), RH max 95% non-condensing Dimensions 160 x 231 x 94 mm (6.3 x 9.1 x 3.7§) Weight 1.2 Kg (2.6 lbs) Ordering Information HI5522 is supplied with HI1131 pH electrode, HI7662-T temperature probe, HI76312 conductivity probe, HI76404W electrode holder, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI700601 electrode cleaning solution sachet (2), HI7082 3.5M KCl electrolyte solution (30 mL), 12 VDC power adapter and instructions. Notes *Uncompensated conductivity (or TDS) is the conductivity (or TDS) value without temperature compensation. read more
next page