Hanna Instruments (M) Sdn Bhd added 12 new photos in Reagents - Checker HC Reagents
May 13, 2024 at 09:39 am —
Hanna Instruments (M) Sdn Bhd added new photo in Testers - pH /ORP
May 10, 2024 at 08:50 am —
HI981030 GroLine Soil pH Tester

HI981030 GroLine Soil pH Tester

RM 658.00

The HI981030 GroLine Soil pH Tester is designed to directly measure soil pH for environmental, agricultural testing. ±0.05 pH accuracy Specialized electrode for spot checking the pH of soil and soil slurries Comes with everything necessary to start measuring right away   Better Features for Better Testing An onscreen stability indicator ensures the highest level of confidence in your results. The selectable auto-off feature prolongs battery life for peace-of-mind and energy savings if the meter is accidentally left on.   Pocket Sized The compact size makes the Soil pH Tester ideal for on-the-go testing. A large LCD display provides at-a-glance readings from any angle and single button operation streamlines the testing process for any user.   Long Battery Life The included CR2032 Li-ion battery provides up to 1000 hours of continuous use. The battery icon will blink to let you know when it is time to change the battery so you never miss a measurement.   PVDF Body with a Removable Sleeve Polyvinylidene Fluoride (PVDF) is a food-grade plastic that is resistant to abrasion and chemical solvent. The PVDF outer junction sleeve can be removed and cleaned. Once cleaned, adding a small amount of supplied gel electrolyte refreshes the junction, improving measurement speed, and extending the life of the tester. Unique Open Junction Reference The open junction design consists of a solid gel interface between the soil sample and the internal Ag/AgCl reference. The junction can be refreshed by remove the sleeve for quick cleaning and new electrolyte.   Cleaning Solution for Soil & Humus Deposits Your Soil pH Tester comes with cleaning solution that is engineered to keep your electrode free from organic materials found in soil. This concentrated combination of detergents cleans your tester quickly and effectively so that your tester stays in optimum condition. pH 4 & 7 Buffer Sachets When performing a pH calibration it is important that the correct buffers are used. We include some start buffers to get you going. The single-use sachets are individually sealed, with a clear lot number and expiration date, so you use fresh buffer each time you calibrate.   Storage Solution Proper storage of your electrode will ensure reliable measurements and a long electrode life. Our storage solution is specially formulated to keep the pH glass hydrated while minimizing organic growth.   More Information SKU HI981030 Product Name GroLine Soil pH Tester - HI981030 Quote Required Yes pH Range 0.00 to 12.00 pH pH Resolution 0.01 pH pH Accuracy ±0.05 pH @ 25 °C / 77 °F pH Calibration automatic one or two-point pH Electrode pH electrode with replaceable bridge electrolyte Automatic Shut-Off user selectable Battery Type/Life CR2032 lithium ion battery (1) / approximately 1000 hours of continuous use Environment 0 to 50°C (32 to 122°F); RH 95% max Dimensions 50 x 151 x 21 mm (2 x 5.9 x 0.9”) Weight 44 g (1.6 oz.) Ordering Information HI981030 is supplied with built in soil pH electrode, HI70004 pH 4.01 buffer solution sachet (2), HI70007 pH 7.01 buffer solution sachet (2), HI700630 electrode cleaning solution for soil deposits sachet (1), HI700664 electrode cleaning solution for humus deposits sachet (1), HI9072 storage solution (13 ml), HI9071 replacement bridge electrolyte, instruction manual, instrument quality certificate, and plastic carrying case read more
Hanna Instruments (M) Sdn Bhd added 3 new photos in Photometers - Checker® HC Colorimeters
May 8, 2024 at 08:34 am —
HI782 Marine Nitrate High Range Checker HC
HI781 Marine Low Range Nitrate Checker HC
HI784 Marine Line Ammonia Checker HC
Hanna Instruments (M) Sdn Bhd added 2 new photos in Photometers - Portable Photometers
May 7, 2024 at 10:39 am —
HI97738 Chlorine Dioxide Portable Photometer with CAL Check
HI97749 Chromium (VI) Low-Range Portable Photometer with CAL Check
Hanna Instruments (M) Sdn Bhd added new photo in Photometers - Portable Photometers
May 7, 2024 at 08:50 am —
HI97779 Chlorine Dioxide (Rapid) Photometer with CAL Check

HI97779 Chlorine Dioxide (Rapid) Photometer with CAL Check

RM 1,672.00

HI97779 is an advanced portable photometer for the measurement of chlorine dioxide in water. This meter offers a superior optical system that utilizes a reference detector and narrow band interference filters for extremely fast and repeatable measurements.   No warm up time before taking a measurement Tutorial mode for step-by-step instructions CAL Check to verify meter performance Used primarily as a disinfectant in drinking water and in various industrial processes, chlorine dioxide is a highly effective, environmentally friendly microbiocide. Chlorine dioxide is safe, potent, and does not produce trihalomethanes, the disinfection byproduct characteristic of chlorine use. The HI97779 uses an adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 4500 ClO2D to measure chlorine dioxide concentrations of less than 2.00 mg/L (ppm). When the chlorophenol red reagent is added to samples containing chlorine dioxide, the purple hue from the reagent will lessen. The greater the concentration, the greater the discoloration. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complementary color, and the emitted radiation is dependent upon concentration. For chlorine dioxide determination, a narrow band interference filter at 525 nm allows only green-yellow light to be emitted and passed through the sample cuvette. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases. Using a pre-programmed curve a result is then displayed. The HI97779 has an innovative optical system that offers superior performance in accuracy, repeatability, and the short amount of time it takes to perform a measurement. This compact, waterproof meter is extremely user friendly with a tutorial mode that walks the user graphically, step by step, in performing a measurement. The use of a backlit dot matrix LCD allows the use of virtual keys which makes the operation of the meter very intuitive including selecting different units of measure, reviewing GLP data, recalling the last 50 measurements, and customizing the meter to user preferences. HI97779 is completely waterproof including the cuvette holder that is designed with ridges to protect the optical path from getting scratched by the cuvette and a gasketed battery compartment that holds three common AA batteries. The compact design fits comfortably in the hand for use in the field or on a table for benchtop use. The LCD is backlit for easy viewing under all conditions.   LED that generates very little heat 8 nm narrowband interference filter that is accurate to +/- 1 nm. Reference detector that modulates the voltage to LED for consistent light output.  A concave focusing lens that reduces errors from imperfections in the cuvette.   On-Screen Features CAL Check Advanced features including CAL-Check to verify performance and if necessary, recalibrate. Setup Options Setup options for meter personalization include date and time format, language, and enabling the tutorial mode. Tutorial Mode Tutorial mode for step-by-step instructions to guide a first-time user in how to perform a measurement correctly.   HI97779 FEATURES/BENEFITS: Stable Light Source: The internal reference system of the HI97779 photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement. High Efficiency Light Source: LED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.  High Quality Filters: Improved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error. Greater Light Yield: A focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes. CAL Check Functionality: Hanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.   Large Cuvette Size: The sample cell of the HI97779 fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples. Intuitive Dot Matrix Display: The HI97779 is designed with a backlit, graphic LCD. With virtual keys, a battery status indicator, and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help. Auto-off Protection: The meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life. More Information SKU HI97779-web Product Name Chlorine Dioxide (Rapid) Photometer with CAL Check – HI97779 Quote Required Yes Chlorine Dioxide Range 0.00 to 2.00 mg/L (as ClO2) Chlorine Dioxide Resolution 0.01 mg/L Chlorine Dioxide Accuracy ±0.10 mg/L ±5% of reading at 25 °C Chlorine Dioxide Method adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 4500 ClO2 D Photometer/Colorimeter Light Source LED with 525 nm bandpass filter Photometer/Colorimeter Light Detector silicon photocell Bandpass Filter Bandwidth 8 nm Bandpass Filter Wavelength Accuracy ±1.0 nm Cuvette Type round 24.6 mm diameter (22 mm inside) GLP yes Display 128 x 64 pixel B/W LCD with backlight Logging Memory 50 readings Battery Type/Life 1.5 V AA Alkaline (3 pcs.) / > 800 measurements (without backlight) Automatic Shut-Off after 15 minutes of inactivity (30 minutes before a READ measurement) Environment 0 to 50°C (32 to 122°F); 0 to 100% RH (IP67) Weight 380 g (13.4 oz.) Dimensions 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0'') Ordering Information HI97738C is supplied with CAL-Check standards, cuvettes (2), caps (2), plastic inserts for cuvette, (2), scissors, cuvette cleaning cloth, 1.5V AA batteries (3), instruction manual, and instrument quality certificate packaged in a rugged, thermoformed, carrying case.   read more
Hanna Instruments (M) Sdn Bhd added new photo in Photometers - Benchtop Photometers
May 6, 2024 at 09:43 am —
HI83399-02 Water & Wastewater Multiparameter (with COD) Photometer and pH meter

HI83399-02 Water & Wastewater Multiparameter (with COD) Photometer and pH meter

RM 7,931.00

HI83399 is a compact, multiparameter photometer for measuring key water and wastewater quality parameters. The meter is one of the most advanced photometers available with a innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. 40 key water and wastewater quality parameters with 73 different methods covering multiple ranges are programmed into the meter. Wastewater treatment digestion parameters include COD, Total Nitrogen and Total Phosphorous which are important for monitoring nutrient removal. The HI83399 also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves. To save valuable laboratory benchtop space, the HI83399 doubles as a professional pH meter with its digital pH/temperature electrode input. Now one meter can be used for both photometric and pH measurements. Advanced optical system Unparalleled performance from a benchtop photometer Digital pH electrode input Save valuable bench space with one meter that works both as a photometer and as a laboratory pH meter Water and Wastewater Treatment Digestion Parameters Allows measurement of COD, Total Nitrogen and Total Phosphorus HI83399 benchtop photometer measures 40 different key water and wastewater quality parameters using 73 different methods that allow for multiple ranges and variations in chemistry for specific applications. The Chemical Oxygen Demand (COD) parameter is included for industrial and municipal wastewater treatment. The Phosphorous and Nitrogen parameters included are beneficial to municipal wastewater treatment customers that need to monitor their biological and chemical nutrient removal process. This photometer features an innovative optical system that uses LEDS, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source ensures accurate and repeatable photometric readings every time. A digital pH electrode input is provided allowing the user to measure pH by a traditional glass electrode. The digital pH electrode has a built in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement. Two USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery. The HI83399 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the 5 wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for education to teach the concept of absorbance by using the Beer-Lambert Law.   Features/Benefits: Backlit 128 x 64 Pixel Graphic LCD Display Backlit graphic display allows for easy viewing in low light conditions The 128 x 64 Pixel LCD allows for a simplified user interface with virtual keys  and on-screen help to guide the user through use of the meter Built-in Reaction Timer for Photometric Measurements The measurement is taken after the countdown timer expires. Countdown timer ensures that all readings are taken at the appropriate reaction intervals regardless of user for better consistency in measurements Absorbance mode Hanna's exclusive CAL Check cuvettes for validation of light source and detector Allows for the user to plot concentration versus absorbance for a specific wavelength for use with user supplied chemistry or for teaching principles of photometry Units of Measure Appropriate unit of measure along with chemical form is displayed along with reading Result Conversion Automatically convert readings to other chemical forms with the touch of a button Cuvette Cover Aids in preventing stray light from affecting measurements Digital pH Electrode Input Measure pH and temperature with a single probe Good Laboratory Practice (GLP) to track calibration information including date, time, buffers used, offset and slope for traceability pH CAL Check alerts user to potential problems during the calibration process Space saving having a pH meter and photometer built into one meter Data Logging Up to 1000 photometric and pH readings can be stored by simply pressing the dedicated LOG button. Logged readings are just as easily recalled by pressing the RCL button Sample ID and User ID information can be added to a logged reading using alphanumeric keypad Connectivity Logged readings can be quickly and easily transferred to a flash drive using the USB-A host port or to a computer using the micro USB-B port Data is exported as a .CSV file for use with common spreadsheet programs Battery Status Indicator Indicates the amount of battery life left Error Messages Photometric error messages include no cap, high zero, and standard too low pH calibration messages include clean electrode, check buffer and check probe On-screen Features Method Selection Users can easily select any one of the 60 measurement methods via the dedicated METHOD button. Data Logging Up to 1000 measurement readings can be logged with user and sample ID and recalled for future use. pH Measurement Mode Selecting the pH measurement mode allows for the photometer to be used as a professional pH meter with many features including temperature compensated measurements, automatic two point calibration, and GLP.   Digestion Parameters Features Cuvette Adapter The HI83399 is supplied with a 16 mm cuvette adapter that accepts digestion vials. Digestion Vial Methods Compatible with COD (EPA, ISO, and mercury free methods), Nitrogen and Phosphorous reagetns packaged in 16 mm digestion vial. Reagents are sold separately. COD Reactor for Digestion Vials A COD reactor is used to heat the digestion vials. The digestion vials must be heated to a specific temperature for a period time making the HI839800 an important accessory required to have a complete wastewater treatment monitoring system.   Advanced Optical System HI83300 is designed with an innovative optical system that incorporates a beam splitter so that light can be used for absorbance readings and for a reference detector. The reference detector monitors the intensity of light and modulates when there is drift due to power fluctuation or the heating of the optical components. Each part has an important role in providing unparalleled performance from a photometer.       High Efficiency LED Light Source An LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components an electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue/violet light output. High Quality Narrow Band Interference Filters The narrow band interference filter not only ensure greater wavelength accuracy (+/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error. Reference Detector for a Stable Light Source A beam splitter is used as part of the internal reference system of the HI83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement. Large Cuvette Size The sample cell of the HI83300 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples. Focusing Lens for Greater Light Yield Adding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.   SKU HI83399-02 Product Name Water & Wastewater Multiparameter (with COD) Photometer and pH meter - HI83399 Quote Required Yes pH Range Photometer pH Resolution Photometer pH Accuracy Photometer pH Calibration Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01) pH Temperature Compensation Automatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used pH CAL Check (electrode diagnostics) clean electrode and check buffer/check probe displayed during calibration pH Method Photometer pH-mV Range ±1000 mV pH-mV Resolution 0.1 mV pH-mV Accuracy ±0.2 mV Dissolved Oxygen Range 0.0 to 10.0 mg/L (as O2) Dissolved Oxygen Resolution 0.1 mg/L Dissolved Oxygen Accuracy ±0.4 mg/L ±3% of reading Dissolved Oxygen Measurement Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method Absorbance Range 0.000 to 4.000 Abs Absorbance Resolution 0.001 Abs Absorbance Accuracy +/-0.003Abs @ 1.000 Abs Alkalinity Range Freshwater Alkalinity Resolution 1 mg/L Alkalinity Accuracy ±5 mg/L ±5% of reading Alkalinity Method Colorimetric method Aluminum Range 0.00 to 1.00 mg/L (as Al3+) Aluminum Resolution 0.01 mg/L Aluminum Accuracy ±0.04 mg/L ±4% of reading Aluminum Method Adaptation of the aluminon method Ammonia Range Low Range Ammonia Resolution Low and Medium Range Ammonia Accuracy Low Range Ammonia Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method Anionic Surfactants Range 0.00 to 3.50 mg/L (as SDBS) Anionic Surfactants Resolution 0.01 mg/L Anionic Surfactants Accuracy ±0.04 mg/L ±3% of reading Anionic Surfactants Method Adaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS Bromine Range 0.00 to 8.00 mg/L (as Br2) Bromine Resolution 0.01 mg/L Bromine Accuracy ±0.08 mg/L ±3% of reading Bromine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method. Calcium Range Freshwater Calcium Resolution 1 mg/L Calcium Accuracy Freshwater Calcium Method Freshwater Chemical Oxygen Demand Range Low Range Chemical Oxygen Demand Resolution 1 mg/L Chemical Oxygen Demand Accuracy Low Range Chemical Oxygen Demand Method Adaptation of the USEPA 410.4 ISO dichromate methods Mercury-free dichromate green method (LR & MR); dichromate method (HR) Chloride Range 0.0 to 20.0 mg/L (as Cl⁻) Chloride Resolution 0.1 mg/L Chloride Accuracy ±0.5 mg/L ±6% of reading at 25 °C Chlorine Dioxide Range 0.00 to 2.00 mg/L (as ClO2) Chlorine Dioxide Resolution 0.01 mg/L Chlorine Dioxide Accuracy ±0.10 mg/L ±5% of reading Chlorine Dioxide Method Adaptation of the Chlorophenol Red method. Free Chlorine Range 0.00 to 5.00 mg/L (as Cl2) Ultra Low Range Free Chlorine Resolution 0.01 mg/L Ultra Low Range Free Chlorine Accuracy ±0.03 mg/L ±3% of reading Ultra Low Range Total Chlorine Range 0.00 to 5.00 mg/L (as Cl2) Ultra Low Range Total Chlorine Resolution 0.01 mg/L Ultra Low Range Total Chlorine Accuracy ±0.03 mg/L ±3% of reading Ultra Low Range Chlorine Method Adaptation of the EPA 330.5 DPD method Free Chlorine (ULR) & Total Chlorine (UHR) Chromium, Hexavalent Range Low Range Chromium, Hexavalent Resolution 1 μg/L Chromium, Hexavalent Accuracy Low Range Chromium, Hexavalent Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide method. Color, Water Range 0 to 500 PCU (Platinum Cobalt Units) Color, Water Resolution 1 PCU Color, Water Accuracy ±10 PCU ±5% of reading Color, Water Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method. Copper Range Low Range Copper Resolution 0.001 mg/L; 0.01 mg/L Copper Accuracy Low Range Copper Method Adaptation of the EPA bicinchoninate method Cyanuric Acid Range 0 to 80 mg/L (as CYA) Cyanuric Acid Resolution 1 mg/L Cyanuric Acid Accuracy ±1 mg/L ±15% of reading Cyanuric Acid Method Adaptation of the turbidimetric method Fluoride Range Low Range Fluoride Resolution 0.01 mg/L; 0.1 mg/L Fluoride Accuracy Low Range Fluoride Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method Hardness, Total Range Low Range Hardness, Total Resolution 1 mg/L Hardness, Total Accuracy Low Range Hardness, Total Method Adaptation of the EPA recommended method 130.1 Hardness, Calcium Range 0.00 to 2.70 mg/L (as CaCO3) Hardness, Calcium Resolution 0.01 mg/L Hardness, Calcium Accuracy ±0.11 mg/L ±5% of reading Hardness, Calcium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method Hardness, Magnesium Range 0.00 to 2.00 mg/L (as CaCO3) Hardness, Magnesium Resolution 0.01 mg/L Hardness, Magnesium Accuracy ±0.11 mg/L ±5% of reading Hardness, Magnesium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method Hydrazine Range 0 to 400 μg/L (as N2H4) Hydrazine Resolution 1 μg/L Hydrazine Accuracy ±4% of full scale reading Hydrazine Method Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88, p-Dimethylaminobenzaldehyde method Iodine Range 0.0 to 12.5 mg/L (as I2) Iodine Resolution 0.1 mg/L Iodine Accuracy ±0.1 mg/L ±5% of reading Iodine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method Iron Range Low Range Iron Resolution 0.001 mg/L; 0.01 mg/L Iron Accuracy Low Range Iron Method Low Range Magnesium Range 0 to 150 mg/L (as Mg2+) Magnesium Resolution 1 mg/L Magnesium Accuracy ±5 mg/L ±3% of reading Magnesium Method Adaptation of the Calmagite method Manganese Range Low Range Manganese Resolution 1 μg/L; 0.1 mg/L Manganese Accuracy Low Range Manganese Method Low Range Molybdenum Range 0.0 to 40.0 mg/L (as Mo6+) Molybdenum Resolution 0.1 mg/L Molybdenum Accuracy ±0.3 mg/L ±5% of reading Molybdenum Method Adaptation of the mercaptoacetic acid method Nickel Range Low Range Nickel Resolution 0.001 mg/L; 0.01 g/L Nickel Accuracy Low range Nickel Method Low Range Nitrate Range 0.0 to 30.0 mg/L (as NO3-- N) 16 mm vial Nitrate Resolution 0.1 mg/L Nitrate Accuracy ±0.5 mg/L ±10% of reading 16 mm vial Nitrate Method Adaptation of the cadmium reduction method 16 mm vial Nitrite Range Freshwater Low Range Nitrite Resolution Freshwater Nitrite Accuracy Freshwater Low Range Nitrite Method Low Range and Seawater Nitrogen, Total Range Low Range Nitrogen, Total Resolution 0.1 mg/L; 1 mg/L Nitrogen, Total Accuracy Low Range Nitrogen, Total Method Chromotropic acid method Oxygen, Scavenger Range 0 to 1000 μg/L (as DEHA) 0.00 to 1.50 mg/L (as Carbohydrazide) 0.00 to 2.50 mg/L (as Hydroquinone) 0.00 to 4.50 mg/L (as ISO-ascorbic acid) Oxygen, Scavenger Resolution 1 μg/L (DEHA); 0.01 mg/L Oxygen, Scavenger Accuracy ±5 μg/L ±5% of reading Oxygen, Scavenger Method Adaptation of the iron reduction method Ozone Range 0.00 to 2.00 mg/L (as O3) Ozone Resolution 0.01 mg/L Ozone Accuracy ±0.02 mg/L ±3% of reading Ozone Method Colorimetric DPD Method Phosphate Range Freshwater Low Range Phosphate Resolution Freshwater Phosphate Accuracy Freshwater Low Range Phosphate Method Freshwater Low Range Phosphorous, Acid Hydrolyzable Range 0.00 to 1.60 mg/L (as P) Phosphorous, Acid Hydrolyzable Resolution 0.01 mg/L Phosphorous, Acid Hydrolyzable Accuracy ±0.05 mg/L or ±5% of reading Phosphorous, Acid Hydrolyzable Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method Phosphorous, Reactive Range Low Range Phosphorous, Reactive Resolution 0.01 mg/L; 0.1 mg/L Phosphorous, Reactive Accuracy Low Range Phosphorous, Reactive Method Low Range Phosphorous, Total Range Low Range Phosphorous, Total Accuracy Low Range Phosphorous, Total Resolution Low Range Phosphorous, Total Method Low Range Potassium Range 0.0 to 20.0 mg/L (as K) Potassium Resolution 0.1 mg/L Potassium Accuracy ±3.0 mg/L ±7% of reading Potassium Method Adaptation of the Turbidimetric Tetraphenylborate method Silica Range Low Range Silica Resolution 0.01 mg/L; 1 mg/L Silica Accuracy Low Range Silica Method Low Range Silver Range 0.000 to 1.000 mg/L (as Ag) Silver Resolution 0.001 mg/L Silver Accuracy ±0.020 mg/L ±5% of reading Silver Method Adaptation of the PAN method Sulfate Range 0 to 150 mg/L (as SO42-) Sulfate Resolution 1 mg/L Sulfate Accuracy ±5 mg/L ±3% of reading Sulfate Method Turbidimetric - Sulfate is precipitated with barium chloride crystals Zinc Range 0.00 to 3.00 mg/L (as Zn) Zinc Resolution 0.01 mg/L Zinc Accuracy ±0.03 mg/L ±3% of reading Zinc Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method Input Channels 1 pH electrode input and 5 photometer wavelengths pH Electrode digital pH electrode (not included) Photometer/Colorimeter Light Source 5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters Photometer/Colorimeter Light Detector silicon photodetector Bandpass Filter Bandwidth 8 nm Bandpass Filter Wavelength Accuracy ±1 nm Cuvette Type round, 24.6 mm Number of Methods 128 max. GLP calibration data for connected pH electrode Display 128 x 64 pixel LCD with backlight Logging Type log on demand with user name and sample ID optional input Logging Memory 1000 readings Connectivity USB-A host for flash drive; micro-USB-B for power and computer connectivity Power Supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included) Battery Type/Life 3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurement Environment 0 to 50.0 oC (32 to 122.0 oF); 0 to 95% RH, non-condensing Weight 1.0 kg (2.2 lbs.) Dimensions 206 x 177 x 97 mm (8.1 x 7.0 x 3.8'') Ordering Information HI83399 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.   read more
Hanna Instruments (M) Sdn Bhd added new photo in Photometers
May 6, 2024 at 08:35 am —
HI801-02 iris Visible Spectrophotometer

HI801-02 iris Visible Spectrophotometer

RM 16,995.00

                                                                                                            Spectrophotometer with split beam optical system, customizable methods, and rechargeable battery   The iris portable spectrophotometer is unlike any of the products we have created in the past. It is different from our photometers as it allows for measurement in the spectrum of all wavelengths of visible light and not just pre–specified wavelengths. Spectrophotometers work by isolating light at specific wavelengths from white light. This compact meter incorporates a number of features that facilitate both fantastic performance and exceptional usability. Superior design for superior results. iris can test a wide variety of analytical measurements and is capable of measuring in a spectral range of 340 nm to 900 nm. With the compact design of its advanced optical system, iris can be used in almost any sized space while providing accurate and consistent results. The split beam optical system allows iris to automatically compensate for any drift in light source, resulting in superior accuracy.   No need for measurement conversions. Whether you are testing for chlorine or running enzymatic assays, our spectrophotometer will conveniently display results in the units that matter most to you. iris can measure in transmittance, absorbance, and concentration based on your need.   The convenience of pre-programmed methods with the option to expand. iris comes pre-programmed with more than 80 commonly used chemical analysis methods to help you get started. Simply update these methods by connecting to a computer or flash drive. Customize your iris with up to 100 personal methods. iris will guide you through the method creation process step-by-step. For added versatility, each method can include up to 10 calibration points, five different wavelengths, and up to five reaction timers. Easily access your favorite methods directly from the home screen to save time. Built in timers make make measuring seamless. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between measurements and users. If you get stuck, the tutorial mode will walk you through the steps.   Change sample size easily. With our universal cuvette holder and auto-recognition feature, cuvette sizes can be changed when needed. The programmed cuvette size will be displayed on the screen every time you test to ensure that the proper path length is being used by the meter when calculating measurements for correct results.   Round Vial Square   Worry free replacements. iris uses a tungsten-halogen lamp for greater energy efficiency, longer service life, and improved light quality for a wide variety of wavelengths. Replacement lamps are shipped pre-aligned and ready for installation so that you can get back to testing.   Designed for dynamic environments. iris' compact profile and long-lasting battery make it easy to set up anywhere in your lab. The rechargeable lithium ion battery lasts for 3,000 measurements, or 8 hours – well over a full day of use out in the field.     Quality data without the hassle. Export your results with a USB drive or direct PC link organized by sample ID, method, or date range. Save data as a .pdf or .csv for maximum data integrity or flexibility – all without the use of specialized software.   Menu navigation that makes sense. Quickly navigate between screens with custom keys, and access your favorite methods directly from the home screen with our “favorite methods” feature.   Sort and share your data. Save data as a .pdf or .csv for maximum data integrity or flexibility. Have the freedom to choose the file format that's best for you. All of your important information is easily visible. With a 6” display, the screen is large and easy to read. The high contrast makes every character on the display stand out even during outdoor use. The wide viewing angle allows for measurements to be seen from far away, so while working around the lab it is not necessary to hover over the meter to see the measurements.   Zero resistance with a capacitive touch pad. Menu buttons are part of the display. Built to be fully sealed and easy to clean, the meter recognizes key touches even through gloves.   Specification:    More Information SKU HI801-02 Product Name iris Visible Spectrophotometer - HI801 Quote Required Yes pH Range 6.5 to 8.5 pH pH Resolution 0.1 pH pH Accuracy ±0.1 pH pH Method Adaptation of the Phenol Red method Dissolved Oxygen Range 0.0 to 10.0 mg/L (as O2 ) Dissolved Oxygen Resolution 0.1 mg/L Dissolved Oxygen Accuracy ±0.4 mg/L ±3% of reading Dissolved Oxygen Measurement Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method Absorbance Range 0.000 to 3.000 Abs Absorbance Resolution 0.001 Abs Absorbance Accuracy 5 mAbs at 0.000-0.500 Abs 1% at 0.500-3.000 Abs Alkalinity Range 0 to 500 mg/L (as CaCO3 ) Alkalinity Resolution 1 mg/L Alkalinity Accuracy ±5 mg/L ±5% of reading Alkalinity Method Colorimetric Method Seawater Alkalinity Range 0 to 300 mg/L (as CaCO3 ) Seawater Alkalinity Resolution 1 mg/L Seawater Alkalinity Accuracy ±5 mg/L ±5% of reading Seawater Alkalinity Method Colorimetric Method Aluminum Range 0.00 to 1.00 mg/L (as Al3+) Aluminum Resolution 0.01 mg/L Aluminum Accuracy ±0.04 mg/L ±4% of reading Aluminum Method Adaptation of the aluminon method. Ammonia Range Low Range Ammonia Resolution Low and Medium Range Ammonia Accuracy Low Range Ammonia Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler method. Anionic Surfactants Range 0.00 to 3.50 mg/L (as SDBS) Anionic Surfactants Resolution 0.01 mg/L Anionic Surfactants Accuracy ±0.04 mg/L ±3% of reading Anionic Surfactants Method Adaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS Bromine Range 0.00 to 8.00 mg/L (as Br2 ) Bromine Resolution 0.01 mg/L Bromine Accuracy ±0.08 mg/L ±3% of reading Bromine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method Calcium Range 0 to 400 mg/L (as Ca2+) Calcium Resolution 1 mg/L Calcium Accuracy ±10 mg/L ±5% of reading Calcium Method Adaptation of the Oxalate method Carbon Dioxide Range 0.00 to 2.00 mg/L (as ClO2 ) Carbon Dioxide Resolution 0.01 mg/L Carbon Dioxide Accuracy ±0.10 mg/L ±5% of reading Carbon Dioxide Method Adaptation of the Chlorophenol Red method Chemical Oxygen Demand Range Low Range Chemical Oxygen Demand Resolution 1 mg/L Chemical Oxygen Demand Accuracy Low Range Chemical Oxygen Demand Method Adaptation of the USEPA 410.4 Chloride Range 0.0 to 20.0 mg/L (as Cl) Chloride Resolution 0.1 mg/L Chloride Accuracy ±0.5 mg/L ±6% of reading Chloride Method Adaptation of the mercury(II) thiocyanate method Chlorine Dioxide Range 0.00 to 2.00 mg/L (as ClO2 ) Chlorine Dioxide Resolution 0.01 mg/L Chlorine Dioxide Accuracy ±0.10 mg/L ±5% of reading Chlorine Dioxide Method Adaptation of the Chlorophenol Red method Free Chlorine Range Ultra Low Range Free Chlorine Resolution Ultra Low Range Free Chlorine Accuracy Ultra Low Range Total Chlorine Range Ultra Low Range Total Chlorine Resolution Ultra Low Range Total Chlorine Accuracy Ultra Low Range Chromium, Hexavalent Range Low Range Chromium, Hexavalent Resolution Low Range Chromium, Hexavalent Accuracy Low Range Chromium, Hexavalent Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687, Diphenylcarbohydrazide method Color, Water Range 0 to 500 PCU (Platinum Cobalt Units) Color, Water Resolution 1 PCU Color, Water Accuracy ±10 PCU ±5% of reading Color, Water Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method Color, Maple Syrup Range 0.00 to 100.00 %T Color, Maple Syrup Resolution 0.01 %T Color, Maple Syrup Accuracy ±3% of reading Color, Maple Syrup Method Direct measure Copper Range Low Range Copper Resolution Low Range Copper Accuracy Low Range Copper Method Adaptation of the EPA method Cyanide Range 0.000 to 0.200 mg/L (as CN-) Cyanide Resolution 0.001 mg/L Cyanide Accuracy ±0.005 mg/L ±3% of reading Cyanide Method Pyridine-Pyrazalone Cyanuric Acid Range 0 to 100 mg/L (as CYA) Cyanuric Acid Resolution 1 mg/L Cyanuric Acid Accuracy ±1 mg/L ±15% of reading Cyanuric Acid Method Adaptation of the turbidimetric method Fluoride Range Low Range Fluoride Resolution Low Range Fluoride Accuracy Low Range Fluoride Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method Hardness, Total Range Low Range Hardness, Total Resolution 1 mg/L Hardness, Total Accuracy Low Range Hardness, Total Method Adaptation of the EPA recommended method 130.1 Hardness, Calcium Range 0.00 to 2.70 mg/L (as CaCO3 ) Hardness, Calcium Resolution 0.01 mg/L Hardness, Calcium Accuracy ±0.11 mg/L ±5% of reading Hardness, Calcium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method Hardness, Magnesium Range 0.00 to 2.00 mg/L (CaCO3 ) Hardness, Magnesium Resolution 0.01 mg/L Hardness, Magnesium Accuracy ±0.11 mg/L ±5% of reading Hardness, Magnesium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method Hydrazine Range 0 to 400 µg/L (as N2H4 ) Hydrazine Resolution 1 µg/L Hydrazine Accuracy ±4% of full scale reading Hydrazine Method Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385, p-Dimethylaminobenzaldehyde method Iodine Range 0.0 to 12.5 mg/L (as I2 ) Iodine Resolution 0.1 mg/L Iodine Accuracy ±0.1 mg/L ±5% of reading Iodine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method Iron Range Low Range Iron Resolution Low Range Iron Accuracy Low Range Iron Method Low Range Magnesium Range 0 to 150 mg/L (as Mg2+) Magnesium Resolution 1 mg/L Magnesium Accuracy ±5 mg/L ±3% of reading Magnesium Method Adaptation of the Calmagite method Manganese Range Low Range Manganese Resolution Low Range Manganese Accuracy Low Range Manganese Method Low Range Molybdenum Range 0.0 to 40.0 mg/L (as Mo6+) Molybdenum Resolution 0.1 mg/L Molybdenum Accuracy ±0.3 mg/L ±5% of reading Molybdenum Method Adaptation of the mercaptoacetic acid method Nickel Range Low Range Nickel Resolution Low Range Nickel Accuracy Low Range Nickel Method Low Range Nitrate Range 0.0 to 30.0 mg/L (as NO3 - N) Chromotropic Acid Nitrate Resolution 0.1 mg/L Nitrate Accuracy ±0.5 mg/L ±10% of reading Chromotropic Acid Nitrate Method Adaptation of the cadmium reduction method Chromotropic Acid Nitrite Range Marine Ultra Low Range Nitrite Resolution Marine Ultra Low Range Nitrite Accuracy Marine Ultra Low Range Nitrite Method Marine Ultra Low Range Nitrogen, Total Range Low Range Nitrogen, Total Resolution Low Range Nitrogen, Total Accuracy Low Range Nitrogen, Total Method Chromotropic acid method Oxygen, Scavenger Range Carbohydrazide Oxygen, Scavenger Resolution Carbohydrazide Oxygen, Scavenger Accuracy Carbohydrazide Oxygen, Scavenger Method Adaptation of the iron reduction method Ozone Range 0.00 to 2.00 mg/L (as O3 ) Ozone Resolution 0.01 mg/L Ozone Accuracy ±0.02 mg/L ±3% of reading Ozone Method Colorimetric DPD Method Phosphate Range Low Range Phosphate Resolution Low Range Phosphate Accuracy Low Range Phosphate Method Low Range Phosphorous, Acid Hydrolyzable Range 0.00 to 1.60 mg/L (as P) Phosphorous, Acid Hydrolyzable Resolution 0.01 mg/L Phosphorous, Acid Hydrolyzable Accuracy ±0.05 mg/L or ±5% of reading Phosphorous, Acid Hydrolyzable Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method. Phosphorous, Reactive Range Low Range Phosphorous, Reactive Resolution Low Range Phosphorous, Reactive Accuracy Low Range Phosphorous, Reactive Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method. Phosphorous, Total Range Low Range Phosphorous, Total Accuracy Low Range Phosphorous, Total Resolution Low Range Phosphorous, Total Method Low Range Potassium Range Low Range Potassium Resolution Low Range Potassium Accuracy Low Range Potassium Method Adaptation of the Turbidimetric Tetraphenylborate method Silica Range Low Range Silica Resolution Low Range Silica Accuracy Low Range Silica Method Low Range Silver Range 0.000 to 1.000 mg/L (as Ag) Silver Resolution 0.001 mg/L Silver Accuracy ±0.020 mg/L ±5% of reading Silver Method Adaptation of the PAN method Sulfate Range 0 to 150 mg/L (as SO42-) Sulfate Resolution 1 mg/L Sulfate Accuracy ±5 mg/L ±3% of reading Sulfate Method Sulfate is precipitated with barium chloride crystals Zinc Range 0.00 to 3.00 mg/L (as Zn) Zinc Resolution 0.01 mg/L Zinc Accuracy ±0.03 mg/L ±3% of reading Zinc Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method Wavelength Range 340 to 900 nm Wavelength Resolution 1 nm Wavelength Accuracy ±1.5 nm Measurement Modes Transmittance (% T), absorbance (abs), concentration with choice of units (ppm, mg/L, ppt, ºf, ºe, ppb, meq/L, μg/L, PCU, Pfund, pH, dKH, ºdH, meq/kg or no measurement unit) Wavelength Selection automatic, based on the selected method (editable for user methods only) Optical System split beam sample and reference light detectors Wavelength Calibration internal, automatic at power-on, visual feedback Data Points Stored up to 9999 measured values Export Capability .csv file format, .pdf file format Connectivity (1) USB - A (mass storage host); (1) USB - B (mass storage device) Power Supply 15 VDC power adapter; 10.8 VDC Li-Ion rechargeable battery Battery Type/Life 3000 measurements or 8 hours Environment 0 to 50 °C (32 to 122 °F); 0 to 95% RH Weight 3 kg (6.6 lbs) Dimensions 155 x 205 x 322 mm (6.1 x 8.0 x 12.6'') Ordering Information HI801 is supplied with 22 mm sample cuvette and cap (4), 10 mm square, 13 mm round and 16 mm round cuvette adapters, cloth for wiping cuvettes, scissors, USB cable, lithium ion rechargeable battery, 115VAC to 15VDC power adapter, USB drive, instruction manual, and instrument quality certificate.   read more
Hanna Instruments (M) Sdn Bhd added new photo in Monitors & Dataloggers
May 6, 2024 at 08:22 am —
HI146-00 Pronto Water-resistant Wall-Mounted Precision Thermometer (°C)

HI146-00 Pronto Water-resistant Wall-Mounted Precision Thermometer (°C)

RM 488.00

The HI146-00 is a high accuracy thermometer with a professional grade probe attached to a flexible 2 m (6.6’) cable. Monitor the exact temperature of any product continuously and easily observe it on the LCD display. CAL Check™ feature to confirm that the thermometer is working correctly. Meets HAACP requirements. Ideal for monitoring the temperatures of liquids, semi-solids, and refrigerated foods. Details The HI146-00 is a high accuracy thermometer with a professional grade probe and a flexible 2 m cable. The CAL CHECK® feature is incorporated into its function to allow you to confirm the accuracy of the meters any time. You can monitor the exact temperature of any product continuously and easily observe it on the LCD display. HI-146-00 can be easily carried from station to station or installed in a fixed position using the moulded eye and a wall mount probe holder. With its compact and simplified design featuring a fixed stainless steel probe and optional probe holder, this thermometer is ideal for monitoring the temperatures of liquids, semi-solids and refrigerated foods. Key features HACCP compliant CAL CHECK® feature Stainless steel temperature probe Water resistant SKU HI146-00 Product Name Pronto Water-resistant Wall-Mounted Precision Thermometer (°C) HI146-00 Quote Required Yes Temperature Range -50.0 to 150.0°C Temperature Resolution 0.1°C Temperature Accuracy ±0.3°C (-20 to 90°C); ±0.5°C (outside) Temperature Probe stainless steel probe (fixed) with 2 m (6.6’) cable; 160 x dia 3 mm (6.3 x dia 0.1’’) Battery Type/Life 1.5V AA / approximately 5 years Environment IP54; 0 to 50°C (32 to 122°F); RH max 95% Dimensions 86 x 110 x 43 mm (3.4 x 4.3 x 1.7’’) Weight 150 Ordering Information HI146-00 (Pronto) is supplied with stainless steel temperature probe, battery and instructions. Probe Type (sensor) stainless steel probe (fixed) with 2 m (6.6’) cable; 160 x dia 3 mm (6.3 x dia 0.1’’) read more
Hanna Instruments (M) Sdn Bhd added new photo in Monitors & Dataloggers
May 3, 2024 at 02:17 pm —
HI147-00 Checkfridge™ Remote Sensor Thermometer

HI147-00 Checkfridge™ Remote Sensor Thermometer

RM 352.00

The HI147 is a remote temperature sensor ideal for monitoring in food care environments. It contains magnets for easy placement on a metal surface and delivers high accuracy measurements over a wide temperature range. CAL Check™ Magnetized Clear Display The HI147 is a remote temperature ideal for monitoring in food care environments. It contains magnets for easy placement on a metal surface and delivers high accuracy measurements over a wide temperature range. The thermometer’s unique CAL Check™ feature allows for an internal calibration of the device with the flick of a switch, thereby alleviating the time preparing an ice bath.   Features at-a-glance CAL Check™  - The thermometer’s unique CAL Check™ feature allows for an internal calibration of the device with the flick of a switch, thereby alleviating the time preparing an ice bath. Magnetized - Two magnets located on the back of the device all for easy placement on the outside of a refrigerator or metal cabinet. Food Compatible Cable - The thermometer is specially designed with a food compatible cable for continuous monitoring of temperature in food care environments.   SKU HI147-web Product Name Checkfridge™ Remote Sensor Thermometer - HI147 Quote Required Yes Temperature Range HI147-00 -50.0 to 150.0°C HI147-01 -58.0 to 302.0°F Temperature Resolution HI147-00 0.1°C HI147-01 0.1°F (-58.0 to 199.9°F) 1°F (200 to 302°F) Temperature Accuracy HI147-00 ±0.3°C (-20 to 90°C); ±0.5°C (outside) HI147-01 ±0.6°F (-4 to 194°F); ±1°F (outside) Battery Type/Life 1.5V AAA / approximately 3 years of continuous use Environment 0 to 50°C (32 to 122°F); RH max 95% Dimensions 93 x 39 x 31 mm (3.7 x 1.5 x 1.2’’) Weight 60 g (2.1 oz.) Ordering Information HI147 is supplied with battery and instructions.   read more
Hanna Instruments (M) Sdn Bhd added 2 new photos in Benchtop Meters - Oxygen, Dissolved
May 3, 2024 at 01:45 pm —
HI6421P Advanced Dissolved Oxygen Benchtop Meter with Polarographic DO Probe
HI6421 Advanced Dissolved Oxygen Benchtop Meter with Optical DO Probe (opdo®)
next page