0

Hanna Instruments (M) Sdn Bhd
11A, Jalan PJS 11/20,
Bandar Sunway,
46150 Petaling Jaya,
Selangor, Malaysia.
+603-5638 9940

Penang Branch Office
Hanna Instruments (M) Sdn Bhd
N0. 303-2-27, Krystal Point,
Jalan Sultan Azlan Shah,
11900 Sungai Nibong,
Penang, Malaysia.
+604-638 4558
+604-645 4558
penang@hannamalaysia.com

Sabah Branch Office
Hanna Instruments (M) Sdn Bhd

No. 4-1, 1st Floor,
Plaza Kingfisher,
Jalan Plaza Kingfisher 5,
Inanam, 88450 Kota Kinabalu,
Sabah, East Malaysia.
088-382 941
088-382 942
sabah@hannamalaysia.com


HI731335 Caps for Glass Cuvette Used with HI96 Series Portable Photometers (4 pcs)

Previous 1 / 2 Next

HI731335 Caps for Glass Cuvette Used with HI96 Series Portable Photometers (4 pcs) Photometers Accessories
RM 80.00
200 g
In Stock


The HI731335 are the replacement caps that screw on the glass cuvettes used with the HI96 series portable photometers. Each cap has a locking indexing tab that ensures the cuvette is inserted into the photometer in the same position. The caps are also used to block any light that would interfere with the optically based measurement. The HI731335 includes 4 caps.
  • Locking index tab for proper alignment in the photometer
  • Light blocking to prevent stray light from entering

When using a photometer it is important to insert the cuvette in the same position when performing a blank measurement (zero) and a read with reacted sample in order to maintain a consistent path length in accordance with the Beer-Lambert Law (see below).  The HI731335 have a locking index tab in the cap that fits with the HI96 series photometers to ensure that the cuvette is inserted in the same orientation each time.

 

The quantity of radiation absorbed is given by the Beer-Lambert Law:

A = log Io/I

 

Absorbance is also given by: A= ελ • C • l where:

A is a dimensionless number

ελ the proportionality constant, is called the molar extinction coežcient or molar absorptivity; it is a constant for a given substance, provided the temperature and wavelength are constant [L/(mol•cm)]

C is the concentration of the substance (mol/liter)

is theoptical distance light travels through sample (cm)


The HI731335 are the replacement caps for glass cuvettes that are supplied with all HI96 series portable photometers. The are also designed to keep any stray light from entering the sample cuvette holder of the optically based system. 

 




 

More Information
SKU HI731335
Product Name Caps for Glass Cuvette Used with HI96 Series Portable Photometers (4 pcs) - HI731335
Quote Required Yes
Notes Package
Quantity 4

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
Recent Updates
Subscribe Newsletter