HI5413 Glass Body Calomel Reference Electrode for Samples with Suspended Solids

Previous 1 / 34 Next

HI5413 Glass Body Calomel Reference Electrode for Samples with Suspended Solids ISE Electrodes & Probes
RM 873.00
SKU: HI5413
500 g
In Stock


The HI5413 is a glass body, refillable, single junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a PTFE sleeve junction in the outer reference cell, calomel references, and is made for use in temperatures ranging from -5 to 60°C.

This design consideration is made for measurements in samples with suspended solids, and can be used in a variety of titrations.

  • Half-Cell Design
  • Calomel References
  • PTFE Sleeve Junction

Details

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

The HI5413 uses a glass body, calomel references, PTFE sleeve junction and is refillable with 3.5M KCl.



Glass Body

The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allow for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the equilibrium the steadier the reference potential.





PTFE Sleeve Junction

Conventional pH electrodes use ceramic junctions that clog quickly when used in samples with high amounts of particulates. When the junction is clogged, the electrode does not function. The use of a polytetrafluoroethylene (PTFE) sleeve junction prevents clogging of the junction and allows proper flow of the liquid electrolyte. As a result, pH electrodes with sleeve junctions stay fresh up to 20 times longer than conventional electrodes.
 




Refillable

The HI5413 is a refillable reference electrode. Since it is a single junction calomel electrode the fill solution is the HI7082 3.5M KCl. This solution does not contain any silver as with single junction silver/silver chloride reference electrodes. The absence of silver will prevent any silver precipitate from forming at the junction surface and clogging it. Clogging of the junction will result in drifty and erratic readings.



4 mm Connector

The HI5413 uses a 4 mm banana connector. This type of connector is easily plugged into the reference input on suitable meters. Other type of connectors include BNC, DIN, screw type, T-type, and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.


 

 

Specifications

Body Material glass
Reference single, Hg/Hg₂Cl₂
Junction / Flow Rate PTFE
Electrolyte 3.5M KCl
Max Pressure 0.1 bar
Diameter 10 mm
Body Length / Overall Length 120 mm / 175.5 mm
Recommended Operating Temperature -5 to 60°C (23 to 140°F)
Cable 1 m (3.3')
Connection banana
Applications samples with suspended solids


 
Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
Recent Updates
Subscribe Newsletter