HI38018-200 Free Chlorine (Low and Medium Range) Test Kit Replacement Reagents (200 tests)

Previous 18 / 27 Next

HI38018-200 Free Chlorine (Low and Medium Range) Test Kit Replacement Reagents (200 tests) Chemical Test Kit Reagents Reagents
RM 281.00
SKU: HI38018-200
600 g
Out of Stock


Download Files

us_hi93701_0_ghs_usa_2.pdf (346.88 KB)
The HI38018-200 are replacement reagents for the colorimetric determination of free chlorine with the HI38018 Free Chlorine Low and Medium Range Test Kit. There are enough reagents for approximately 200 tests to be used with Hanna’s test kit. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.

  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability

Details

The HI38018-200 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate free chlorine measurements with the chemical test kit. These reagents follow the DPD (N,N-diethyl-p-phenylenediamine) method to determine free chlorine concentration. 

For determination of free chlorine, the DPD powder reagent is added to a sample containing chlorine. The reaction between chlorine and the reagent causes a pink colored complex to form; the greater the concentration, the deeper the color. A Checker Disc is included for an accurate, side-by-side, visual analysis to determine free chlorine concentration. These reagents are designed to be used with low range samples that have an expected free chlorine range of 0.00 to 0.70 mg/L (ppm) Cl2 and high range samples that have an expected free chlorine range of 0.0 to 3.5 mg/L (ppm) Cl2.

 

Specifications


 
Package packets
Number of Tests 200
Method DPD

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
Recent Updates
Subscribe Newsletter